Image-Line Mini ACF System
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-53400
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-53400AISI 420 Martensitic

Image-Line Mini ACF System Surgical Retractor Compact Design

4.9 / 5.0•18 Verified OR Evaluations
$10500.00$10582.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $82.00 (1% OFF)
  • Image-Line Mini ACF System designed with a compact configuration for controlled retraction.
  • Modular components provide a defined retraction profile for cervical procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for anterior cervical fusion and cervical surgery applications requiring a reliable retraction instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Image-Line Mini ACF System is a specialized surgical instrument designed for anterior cervical fusion procedures. Its compact and efficient design allows for rapid assembly and precise placement during surgery, ensuring optimal performance in the operating room.

With a durable construction, the Image-Line Mini ACF System provides excellent stability, controlled retraction, and enhanced visualization of the surgical field. The ergonomic handles and optimized geometry reduce surgeon fatigue, making it an essential tool for cervical procedures.

Key Features

  • Compact design for efficient surgical use.
  • Modular components allow for rapid assembly.
  • Ergonomic handles reduce surgeon fatigue.
  • Provides controlled retraction and enhanced visualization.
  • Durable construction ensures long-term reliability.
  • Corrosion-resistant materials for extended use.
  • Designed specifically for anterior cervical fusion procedures.
  • Supports precise placement within the surgical field.

Technical Specifications

SpecificationDetails
Instrument TypeImage-Line Mini ACF System
Overall LengthCompact Design
Working End / Blade / JawModular Components
ConfigurationErgonomic
Primary FunctionControlled Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCervical Surgery

The Image-Line Mini ACF System combines a compact design with modular components for effective controlled retraction in cervical procedures.

Design & Function

The Image-Line Mini ACF System features an ergonomic design that provides a specialized orientation during anterior cervical fusion procedures. The modular components assist in positioning the retractor according to the requirements of the surgical field.

The compact design allows for controlled manual positioning, while the ergonomic handles reduce fatigue for the surgeon. Together, these features provide a practical configuration for cervical procedures requiring a reliable retraction instrument.

Surgical Applications

The Image-Line Mini ACF System may be used for anterior cervical fusion and other cervical surgery applications involving controlled retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Image-Line Mini ACF System before use, paying particular attention to the modular components and ergonomic handles. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Image-Line Mini ACF System appropriately to protect its components and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this instrument?
The overall length is Compact Design.

2. What is the working end / blade or tip design of the instrument?
It features Modular Components.

3. Is this instrument curved or straight?
It features an Ergonomic configuration.

4. What is the Image-Line Mini ACF System used for?
It is designed for controlled retraction in cervical surgery.

5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the retractor within the surgical field.

6. Is this instrument suitable for cervical surgery?
It may be used in anterior cervical fusion and other cervical surgery applications where a reliable retraction instrument is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the functional geometry of the instrument.

8. How should the Image-Line Mini ACF System be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.