
25 x 60mm Image-Trac T-Bar Tissue Retractor
Direct Manufacturer Pricing • Tax Exclusive
- 25 x 60mm Image-Trac T-Bar Tissue Retractor designed with a T-Bar configuration for precise tissue retraction.
- 25 mm working width provides a defined retraction profile for general surgical procedures.
- T-Bar design supports a specialized working orientation within the operative field.
- Suitable for general surgical and lumbar procedure applications requiring a T-Bar retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 25 x 60mm Image-Trac T-Bar Tissue Retractor is a specialized general instrument designed for precise tissue retraction during lumbar procedures. Its 25 mm width allows accurate engagement of tissues in narrow anatomical spaces, while the 60 mm length provides enhanced reach for better operative visibility. The T-bar shape ensures even pressure distribution, reducing tissue trauma and maintaining stability during manipulation.
With an overall length of 25 x 60 mm and a 25 mm working width, this tissue retractor provides a defined retraction profile for general surgical applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 25 x 60 mm overall length for controlled manual handling.
- 25 mm working width provides a defined retraction profile.
- T-Bar configuration for specialized working orientation.
- Designed for precise tissue retraction during lumbar procedures.
- Suitable for general surgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Image-Trac pattern for professional surgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Image-Trac T-Bar Tissue Retractor |
| Overall Length | 25 x 60 mm |
| Working End / Blade / Jaw | 25 mm |
| Configuration | T-Bar |
| Primary Function | Tissue Retraction |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | General Surgery |
The 25 x 60mm Image-Trac T-Bar Tissue Retractor combines a 25 x 60 mm overall length with a 25 mm working width and T-Bar configuration.
Its defined working profile is intended for precise tissue retraction in general surgical applications.
Design & Function
The Image-Trac T-Bar features a T-Bar working configuration designed to provide a specialized orientation during lumbar procedures. The working end design can assist in positioning the retractor according to the requirements of the operative field.
The 25 mm working width provides a defined retraction profile, while the 25 x 60 mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for general surgical procedures requiring a T-Bar retractor.
Surgical Applications
The 25 x 60mm Image-Trac T-Bar Tissue Retractor may be used for general surgical and lumbar procedure applications involving precise tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Image-Trac T-Bar before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Image-Trac T-Bar appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Tissue Retractor?
The overall length is 25 x 60 mm.
2. What is the working end / blade or tip design of the instrument?
It features 25 mm working width.
3. Is this Tissue Retractor curved or straight?
It features a T-Bar configuration.
4. What is a Tissue Retractor used for?
It is designed for controlled tissue retraction in general surgical applications.
5. What clinical advantage does the T-Bar design provide?
The T-Bar design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for general surgery?
It may be used in general surgical and lumbar procedure applications where a T-Bar retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Tissue Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
