Infant Lacl Dilator – very fine tip
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-64467
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-64467AISI 420 Martensitic

Infant Lacrimal Dilator Very Fine Tip

4.9 / 5.0•18 Verified OR Evaluations
$26.00$40.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $14.00 (35% OFF)
  • Infant Lacrimal Dilator Very Fine Tip designed with a straight configuration for gentle lacrimal dilation.
  • Very fine tip provides a defined dilation profile for pediatric procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for pediatric and ophthalmic applications requiring a delicate instrument type.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Infant Lacrimal Dilator Very Fine Tip is a specialized ophthalmic instrument designed for delicate lacrimal procedures in pediatric patients. Its ultra-fine tapered tip allows clinicians to gradually and safely enlarge the punctal opening without causing trauma to surrounding tissue.

With an overall length of and a very fine tip, this dilator provides a defined profile for ophthalmic applications. The design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • Very fine tip provides a defined dilation profile.
  • Specialized configuration for delicate working orientation.
  • Designed for gentle lacrimal dilation procedures.
  • Suitable for pediatric ophthalmic applications.
  • Supports positioning of the working end within the operative field.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeInfant Lacrimal Dilator
Overall Length
Working End / Blade / JawVery fine tip
ConfigurationStraight
Primary FunctionLacrimal Dilation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypePediatric Ophthalmic

The Infant Lacrimal Dilator Very Fine Tip combines a overall length with a very fine tip and straight configuration.
Its defined working profile is intended for gentle lacrimal dilation procedures in pediatric ophthalmic applications.

Design & Function

The Infant Lacrimal Dilator features a straight working configuration designed to provide a specialized orientation during lacrimal dilation. The very fine tip can assist in positioning the working end according to the requirements of the operative field.

The very fine tip provides a defined dilation profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for pediatric procedures requiring a delicate instrument type.

Surgical Applications

The Infant Lacrimal Dilator Very Fine Tip may be used for pediatric and ophthalmic applications involving gentle dilation of the lacrimal punctum and canaliculi. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Infant Lacrimal Dilator before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Infant Lacrimal Dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Infant Lacrimal Dilator?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features very fine tip.

3. Is this Infant Lacrimal Dilator curved or straight?
It features a straight configuration.

4. What is an Infant Lacrimal Dilator used for?
It is designed for controlled lacrimal dilation in pediatric applications.

5. What clinical advantage does the very fine tip provide?
The very fine tip provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for pediatric ophthalmic surgery?
It may be used in pediatric and ophthalmic applications where a delicate instrument type is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Infant Lacrimal Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.