2
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-74951
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-74951AISI 420 Martensitic

Joint, Calcaneal and Small Bone Compressor/Distractors with Speed Lock

4.9 / 5.0•18 Verified OR Evaluations
$340.00 – $440.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

The Joint, Calcaneal & Small Bone Compressor/Distractors with Speed Lock are available in multiple sizes and arm configurations for compatible orthopedic applications. The range includes extra-small and small outspread-arm configurations, plus large outspread and small closed-arm options. All configurations accommodate 1.6 mm and 2.4 mm hole diameters and incorporate a speed-lock configuration with thumbscrews.
sizing
Select an option
Select a configuration above to inspect size specifications and individual photo.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Joint, Calcaneal & Small Bone Compressor/Distractors with Speed Lock are specialized orthopedic instruments designed for compatible compression and distraction applications involving joints, the calcaneal region, and small bones. The range provides multiple sizes and two arm configurations to accommodate different working requirements.

All listed configurations are designed for 1.6 mm and 2.4 mm hole diameters. The instruments feature a Speed Lock configuration, with the supplied options incorporating either outspread or closed arms and thumbscrews as specified.

Available Configurations

Extra Small – Outspread Arms

The Extra Small configuration has an overall length of 4.5" (11.4 cm) and accommodates 1.6 mm and 2.4 mm hole diameters. It features an outspread-arm configuration with Speed Lock and thumbscrew design.

Small – Outspread Arms

The Small outspread-arm configuration measures 6" (15.2 cm) overall and accommodates 1.6 mm and 2.4 mm hole diameters.

Large – Outspread Arms

The Large configuration has an overall length of 8" (20.3 cm) and accommodates 1.6 mm and 2.4 mm hole diameters. It features outspread arms with Speed Lock and thumbscrews.

Small – Closed Arms

The Small closed-arm configuration measures 6" (15.2 cm) overall and accommodates 1.6 mm and 2.4 mm hole diameters. It features closed arms with Speed Lock and thumbscrews.

Design and Configuration

The range provides two primary arm configurations:

  • Outspread Arms: Available in Extra Small, Small, and Large sizes.
  • Closed Arms: Available in Small size.

The available overall lengths range from 4.5" (11.4 cm) to 8" (20.3 cm), allowing selection according to the required instrument size and working configuration.

Speed Lock and Thumbscrews

The instruments are specified with a Speed Lock mechanism and thumbscrew configuration. These features form part of the instrument's mechanical design for controlled adjustment and positioning during compatible applications.

Orthopedic Applications

These compressor/distractors are designed for compatible joint, calcaneal, and small-bone orthopedic applications where controlled compression or distraction is required.

Handling and Use Considerations

Select the instrument configuration according to the intended application, required overall length, arm configuration, and compatible fixation hardware. Use should follow the applicable surgical technique and manufacturer instructions.

Cleaning and Instrument Care

After use, clean the instrument according to validated instrument-processing procedures. Pay particular attention to the holes, arms, Speed Lock mechanism, and thumbscrews during cleaning and inspection.

Sterilization and Inspection

Inspect the instrument for cleanliness, mechanical function, and structural integrity before use. Sterilization should be performed according to the manufacturer's validated instructions and applicable healthcare facility protocols.

Technical Specifications

SpecificationExtra SmallSmall – OutspreadLarge – OutspreadSmall – Closed
Arm ConfigurationOutspreadOutspreadOutspreadClosed
Overall Length4.5" (11.4 cm)6" (15.2 cm)8" (20.3 cm)6" (15.2 cm)
Hole Diameters1.6 & 2.4 mm1.6 & 2.4 mm1.6 & 2.4 mm1.6 & 2.4 mm
Speed LockYesYesYesYes
ThumbscrewsYesYesYesYes

Frequently Asked Questions

What sizes are available?

The range includes Extra Small, Small, and Large configurations, with the Small size available in both outspread and closed-arm designs.

What hole diameters are supported?

All listed configurations accommodate 1.6 mm (0.062") and 2.4 mm (0.094") hole diameters.

What is the smallest configuration?

The Extra Small configuration has an overall length of 4.5" (11.4 cm).

What is the largest configuration?

The Large Outspread Arms configuration has an overall length of 8" (20.3 cm).

Are both outspread and closed-arm configurations available?

Yes. The range includes outspread-arm and closed-arm configurations.

Do the instruments feature a Speed Lock?

Yes. The supplied configurations are specified with a Speed Lock and thumbscrews.