Kerrison Rongeur – Micro, 11″ (275mm), 3mm, 40° Up, Stainless Steel
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-51551
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-51551AISI 420 Martensitic

11″ Micro Kerrison Rongeur 3mm Up 40° Angle

4.9 / 5.0•18 Verified OR Evaluations
$1100.00$1200.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $100.00 (8% OFF)
  • 11″ Micro Kerrison Rongeur designed with a 40° angled configuration for precise bone removal and excision.
  • 3 mm jaw dimension provides a defined cutting profile for neurosurgical procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal surgery applications requiring a micro rongeur.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 11″ Micro Kerrison Rongeur is a specialized neurosurgical instrument designed for precise bone removal in deep spinal and neurosurgical procedures. Its 3mm up-biting jaw and 40° angle provide a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of 11 inches (275 mm) and a 3 mm jaw dimension, this rongeur provides a defined cutting profile for neurosurgical applications. The micro design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 11-inch overall length for controlled manual handling.
  • 3 mm jaw dimension provides a defined cutting profile.
  • 40° angled configuration for specialized working orientation.
  • Designed for precise bone removal and excision.
  • Suitable for neurosurgical and spinal surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Micro pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMicro Kerrison Rongeur
Overall Length11″
Working End / Blade / Jaw3 mm Up-biting Jaw
Configuration40° Angle
Primary FunctionBone Removal and Excision
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical / Spinal Surgery

The 11″ Micro Kerrison Rongeur combines an 11-inch overall length with a 3 mm jaw dimension and 40° angle configuration.
Its defined working profile is intended for precise bone removal and excision in neurosurgical applications.

Design & Function

The Micro Kerrison Rongeur features a 40° angled working configuration designed to provide a specialized orientation during bone preparation. The jaw design can assist in positioning the cutting end according to the requirements of the operative field.

The 3 mm jaw profile provides a defined cutting profile, while the 11-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a micro rongeur.

Surgical Applications

The 11″ Micro Kerrison Rongeur may be used for neurosurgical and spinal surgery applications involving precise bone removal and excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Micro Kerrison Rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Micro Kerrison Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Micro Kerrison Rongeur?
The overall length is 11 inches.

2. What is the working end / blade or tip design of the instrument?
It features 3 mm up-biting jaw.

3. Is this Micro Kerrison Rongeur curved or straight?
It features a 40° angled configuration.

4. What is a Micro Kerrison Rongeur used for?
It is designed for controlled bone removal and excision in neurosurgical applications.

5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgical surgery?
It may be used in neurosurgical and spinal surgery applications where a micro rongeur is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Micro Kerrison Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.