Kerrison Rongeur, Micro, 7″ (175mm), 2mm, 90° Down – Stainless Steel
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-50934
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-50934AISI 420 Martensitic

7″ Kerrison Rongeur Micro 2mm 90° Down

4.9 / 5.0•18 Verified OR Evaluations
$477.00$677.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $200.00 (30% OFF)
  • 7″ Kerrison Rongeur Micro 2mm 90° Down designed with a downward configuration for precise bone removal.
  • 2 mm jaw dimension provides a defined cutting profile for neurosurgical procedures.
  • 90° downward design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal applications requiring a compact instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 7″ Kerrison Rongeur Micro 2mm 90° Down is a specialized neurosurgical instrument designed for precise bone removal in anatomically challenging areas. Its 90° downward angled jaw provides direct access to inferior structures while maintaining clear visualization within the operative field.

With an overall length of 7 inches (175mm) and a 2mm jaw dimension, this Kerrison Rongeur offers enhanced maneuverability in confined spaces, making it ideal for delicate spinal and neurosurgical applications. The compact design supports controlled manual manipulation during procedures.

Key Features

  • 7-inch overall length for enhanced maneuverability.
  • 2 mm jaw dimension provides a defined cutting profile.
  • 90° downward configuration for specialized working orientation.
  • Designed for precise bone removal in neurosurgical applications.
  • Suitable for spinal and neurosurgical procedures.
  • Supports positioning of the working end within the operative field.
  • Specialized Kerrison pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeKerrison Rongeur Micro
Overall Length7″
Working End / Blade / Jaw2 mm
Configuration90° Down
Primary FunctionBone Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 7″ Kerrison Rongeur Micro 2mm 90° Down combines a 7-inch overall length with a 2 mm jaw and 90° downward configuration.
Its defined working profile is intended for precise bone removal in neurosurgical applications.

Design & Function

The Kerrison Rongeur Micro features a 90° downward working configuration designed to provide a specialized orientation during bone removal. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The 2 mm jaw profile provides a defined cutting profile, while the 7-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a compact instrument.

Surgical Applications

The 7″ Kerrison Rongeur Micro 2mm 90° Down may be used for neurosurgical and spinal applications involving precise bone removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Kerrison Rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Kerrison Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Kerrison Rongeur?
The overall length is 7 inches.

2. What is the working end / blade or tip design of the instrument?
It features 2 mm jaw dimension.

3. Is this Kerrison Rongeur curved or straight?
It features a 90° downward configuration.

4. What is a Kerrison Rongeur used for?
It is designed for controlled bone removal in neurosurgical applications.

5. What clinical advantage does the downward configuration provide?
The downward configuration provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal applications where a 90° downward Kerrison Rongeur is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Kerrison Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.