Kleinsasser Orig Forceps .2mm cutting cup up
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-50417
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-50417AISI 420 Martensitic

0.2mm Kleinsasser Original Forceps Upward Cutting Cup

4.9 / 5.0•18 Verified OR Evaluations
$537.00$557.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (4% OFF)
  • 0.2mm Kleinsasser Original Forceps Upward Cutting Cup designed with an upward configuration for precise tissue removal.
  • 0.2 mm cutting cup provides a defined cutting profile for ENT procedures.
  • Upward design supports a specialized working orientation within the operative field.
  • Suitable for ENT and laryngeal surgery applications requiring a specialized cutting forceps.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 0.2mm Kleinsasser Original Forceps Upward Cutting Cup is a specialized ENT instrument designed for precise microsurgical laryngeal procedures. Its ultra-fine cutting cup provides a distinct working orientation that can assist with the accurate removal of delicate tissue, while the upward orientation enhances access and visibility within the operative field.

With an overall length of and a 0.2 mm cutting cup, this forceps provides a defined cutting profile for ENT applications. The ergonomic design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 0.2 mm cutting cup provides a defined cutting profile.
  • Upward configuration for specialized working orientation.
  • Designed for precise tissue removal during laryngeal procedures.
  • Suitable for ENT applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Kleinsasser pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeKleinsasser Original Forceps
Overall Length
Working End / Blade / Jaw0.2 mm cutting cup
ConfigurationUpward
Primary FunctionTissue Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT

The 0.2mm Kleinsasser Original Forceps Upward Cutting Cup combines a overall length with a 0.2 mm cutting cup and upward configuration.
Its defined working profile is intended for precise tissue removal in ENT applications.

Design & Function

The Kleinsasser Original Forceps features an upward working configuration designed to provide a specialized orientation during laryngeal procedures. The cutting cup design can assist in positioning the working end according to the requirements of the operative field.

The 0.2 mm cutting cup provides a defined cutting profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a specialized cutting instrument.

Surgical Applications

The 0.2mm Kleinsasser Original Forceps Upward Cutting Cup may be used for ENT and laryngeal surgery applications involving precise tissue removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Kleinsasser Original Forceps before use, paying particular attention to the cutting cup, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Kleinsasser Original Forceps appropriately to protect its cutting cup and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Forceps?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 0.2 mm cutting cup.

3. Is this Forceps curved or straight?
It features an upward configuration.

4. What is a Forceps used for?
It is designed for controlled tissue removal in ENT applications.

5. What clinical advantage does the upward design provide?
The upward orientation provides enhanced access and visibility for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and laryngeal applications where a specialized cutting forceps is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.