LaBorde Tracheal Dilator with 3 blades
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-50770
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-50770AISI 420 Martensitic

LaBorde Tracheal Dilator with 3 Blades

4.9 / 5.0•18 Verified OR Evaluations
$190.00$208.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $18.00 (9% OFF)
  • LaBorde Tracheal Dilator with 3 Blades designed with a triple blade configuration for controlled tracheal dilation.
  • provides a defined dilation profile for ENT procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for ENT and airway management applications requiring a triple blade dilator.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The LaBorde Tracheal Dilator with 3 Blades is a specialized ENT instrument designed for controlled and effective expansion of the tracheal lumen during airway procedures. Its triple-blade configuration ensures uniform dilation while minimizing trauma to the tracheal mucosa, making it suitable for tracheostomy and laryngotracheal interventions.

With an overall length of and a , this dilator provides a defined dilation profile for ENT applications. The ergonomic handle allows for precise control, enabling gradual and safe dilation during procedures.

Key Features

  • for controlled manual handling.
  • provides a defined dilation profile.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Designed for controlled tracheal dilation during airway procedures.
  • Suitable for ENT and airway management applications.
  • Supports positioning of the working end within the operative field.
  • Specialized LaBorde pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeLaBorde Tracheal Dilator
Overall Length
Working End / Blade / Jaw
ConfigurationTriple Blade
Primary FunctionTracheal Dilation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Airway Management

The LaBorde Tracheal Dilator with 3 Blades combines a overall length with a and a triple blade configuration.
Its defined working profile is intended for controlled tracheal dilation in ENT applications.

Design & Function

The LaBorde Tracheal Dilator features a triple blade configuration designed to provide a specialized orientation during airway procedures. The ergonomic handle allows for precise control, assisting in positioning the working end according to the requirements of the operative field.

The blade dimension provides a defined dilation profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a triple blade dilator.

Surgical Applications

The LaBorde Tracheal Dilator with 3 Blades may be used for ENT and airway management applications involving controlled tracheal dilation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the LaBorde Tracheal Dilator before use, paying particular attention to the working end and blade alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the LaBorde Tracheal Dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this LaBorde Tracheal Dilator?
The overall length is .

2. What is the working end / blade design of the instrument?
It features .

3. Is this LaBorde Tracheal Dilator curved or straight?
It features a triple blade configuration.

4. What is a LaBorde Tracheal Dilator used for?
It is designed for controlled tracheal dilation in ENT applications.

5. What clinical advantage does the ergonomic handle provide?
The ergonomic handle provides precise control for gradual and safe dilation.

6. Is this instrument suitable for airway management?
It may be used in ENT and airway management applications where a triple blade dilator is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the LaBorde Tracheal Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.