Laparoscopic Clip Applicator 10mm LT 300 & LT 400
Direct Manufacturer Pricing • Tax Exclusive
The Laparoscopic Clip Applicator 10 mm LT 300 & LT 400 is a specialized laparoscopic instrument designed to deliver compatible surgical clips through a minimally invasive access port. Its elongated shaft and applicator mechanism support controlled clip placement during procedures where ligation of vessels or other suitable anatomical structures is required.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Laparoscopic Clip Applicator 10 mm LT 300 & LT 400 is a specialized surgical instrument intended for clip application during minimally invasive procedures. Laparoscopic clip applicators allow surgeons to place compatible surgical clips around selected vessels, ducts, or other anatomical structures when mechanical ligation is appropriate. The 10 mm designation identifies the stated instrument diameter, while LT 300 and LT 400 identify the model variants referenced in the product title.
Because laparoscopic procedures are performed through small access incisions, instruments must provide suitable reach, controlled handling, and compatibility with the selected trocar and clip system. Choosing the correct clip applicator is essential for ensuring that the instrument functions as intended within the surgical setup.
Purpose and Surgical Applications
Laparoscopic clip applicators are used to position and close compatible surgical clips around structures requiring ligation. Depending on the procedure and approved clip system, these instruments may be used in general laparoscopic surgery, including selected abdominal procedures where mechanical closure of vessels or ducts is indicated.
The surgeon positions the applicator around the intended structure under appropriate visualization and activates the mechanism to deploy or close the clip according to the device's instructions for use. Correct clip selection, placement, and closure are important for achieving the intended result.
The exact clinical applications of the LT 300 and LT 400 variants should be confirmed with the manufacturer. The product title alone does not establish which clip sizes, cartridge configurations, or surgical procedures are supported.
10 mm Shaft Design
The 10 mm shaft is intended for use within compatible laparoscopic access systems. Its elongated profile allows the working end to reach the operative site through an appropriately sized trocar while the handle remains outside the body.
Shaft length, jaw geometry, and tip orientation influence access and maneuverability within the abdominal cavity. Buyers should verify the overall length and working-end configuration before purchase, particularly when replacing an existing instrument or assembling a procedure-specific laparoscopic set.
Compatibility with a 10 mm trocar must be confirmed against the manufacturer's specifications rather than inferred from diameter alone.
Clip Application Mechanism
The applicator mechanism is designed to position and apply clips compatible with the instrument. Depending on the model, the mechanism may support clip feeding, positioning, and closure through a manually operated handle.
Reliable operation requires the correct clip type and loading procedure. Clips must be compatible with the applicator's design, and the jaws should be positioned appropriately around the target structure before deployment. An incorrectly selected clip or incomplete closure may compromise the intended ligation.
The LT 300 and LT 400 variants should not be assumed to share identical clip compatibility or operating characteristics. Confirm model-specific instructions, supported clips, and loading requirements before use.
Construction and Material
Reusable laparoscopic clip applicators are commonly manufactured using medical-grade stainless steel and other materials suitable for surgical instrumentation. The exact material composition, handle construction, and reusable status of this product should be confirmed with the supplier.
The instrument should be inspected for shaft deformation, jaw misalignment, damage to the clip-loading area, and irregular handle movement. The working end and operating mechanism must function according to the manufacturer's specifications.
Clinical Handling and Benefits
A compatible laparoscopic clip applicator supports mechanical ligation while allowing the surgeon to work through minimally invasive access points. Its elongated shaft helps reach internal operative sites, while the application mechanism provides a controlled method of positioning and closing compatible clips.
Appropriate use depends on selecting the correct instrument model, clip type, and access system. Surgeons should follow the manufacturer's instructions for loading, positioning, deployment, and confirmation of clip closure. The instrument should only be used by trained professionals within its approved indications.
Cleaning, Sterilization, and Maintenance
If supplied as a reusable instrument, the laparoscopic clip applicator must be cleaned, inspected, and sterilized according to the manufacturer's validated instructions. The jaws, shaft, clip-loading area, and handle mechanism may require specific cleaning steps to remove biological material and other residues.
After cleaning, inspect the instrument for damage, corrosion, restricted movement, and any defects that could interfere with clip application. Sterilization must use a validated method compatible with the instrument's materials and design.
Some laparoscopic clip applicators or related components may be intended for single use. Reusability must be verified for each specific model; single-use devices must not be reprocessed for reuse.
Product Selection and Compatibility
Before purchasing the Laparoscopic Clip Applicator 10 mm LT 300 & LT 400, confirm the exact model number, compatible clip type and size, shaft length, trocar requirements, and reusable or single-use status. These details are particularly important when sourcing replacement instruments for an existing laparoscopic system.
Verifying compatibility helps prevent ordering an instrument that cannot be used with the available clips or equipment. Buyers should obtain the manufacturer's technical documentation and instructions for use before clinical deployment.
Key Features
Laparoscopic clip applicator with a stated 10 mm diameter
LT 300 and LT 400 model variants
Designed for placement of compatible surgical clips
Intended for selected minimally invasive surgical procedures
Elongated shaft for access through compatible laparoscopic ports
Mechanism for controlled clip positioning and application
Clip compatibility must be confirmed for each model
Designed for use by trained surgical professionals
Material and reusable status should be verified with the supplier
Cleaning and sterilization must follow manufacturer instructions for reusable models
Product Specifications
Specification | Details |
|---|---|
Product Name | Laparoscopic Clip Applicator |
Model Variants | LT 300 and LT 400 |
Stated Diameter | 10 mm |
Instrument Category | Laparoscopic clip applicator |
Primary Function | Placement and application of compatible surgical clips |
Surgical Specialty | Minimally invasive surgery |
Shaft Length | Not specified |
Jaw Configuration | Confirm with supplier |
Compatible Clip Types | Manufacturer-specific; verify before purchase |
Material | Not specified; confirm manufacturer details |
Reusability | Confirm separately for each model |
Sterilization | Follow model-specific manufacturer instructions |
Packaging | Confirm with supplier |
Frequently Asked Questions
1. What is a 10 mm laparoscopic clip applicator used for?
A 10 mm laparoscopic clip applicator is used to position and apply compatible surgical clips during minimally invasive procedures when mechanical ligation is indicated.
2. What is the difference between the LT 300 and LT 400 models?
The exact differences between LT 300 and LT 400 cannot be established from the product title alone. Buyers should confirm shaft length, clip compatibility, operating mechanism, and other model-specific specifications with the manufacturer.
3. Which surgical clips are compatible with this laparoscopic clip applicator?
Compatibility depends on the specific applicator model and its approved clip system. Confirm the supported clip type, size, and loading configuration before ordering or use.
4. Can a 10 mm laparoscopic clip applicator be used with any 10 mm trocar?
Not necessarily. The stated diameter does not guarantee compatibility with every trocar. The applicator's external dimensions and the manufacturer's access-system requirements should be checked.
5. Is the Laparoscopic Clip Applicator LT 300 or LT 400 reusable?
Reusability depends on the specific device. Confirm whether each model is reusable or single-use and follow the corresponding manufacturer instructions.
6. How should a reusable laparoscopic clip applicator be sterilized?
It must be cleaned and sterilized according to the manufacturer's validated instructions. The shaft, jaws, clip-loading area, and handle mechanism should be inspected as part of reprocessing.
7. What should buyers check before purchasing the LT 300 or LT 400?
Verify the exact model, instrument diameter, shaft length, compatible clip system, trocar requirements, material, and reusable or single-use status before purchasing.