8″ Lempert Endaural Curette Size 0
Direct Manufacturer Pricing • Tax Exclusive
- 8″ Lempert Endaural Curette Size 0 designed with a curved configuration for precise tissue removal and debris clearance.
- Size 0 working end provides a defined removal profile for otologic procedures.
- Curved design supports a specialized working orientation within the operative field.
- Suitable for ENT and otologic surgery applications requiring a curved curette.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8″ Lempert Endaural Curette Size 0 is a specialized otologic instrument designed for endaural and middle ear procedures requiring extended reach and fine control. Its fine working end provides a distinct working orientation that can assist with positioning the tip within the operative field.
With an overall length of 8 inches and a Size 0 working end, this curette provides a defined profile for precise tissue removal. The design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 8-inch overall length for controlled manual handling.
- Size 0 working end provides a defined removal profile.
- Curved configuration for specialized working orientation.
- Designed for precise tissue removal and debris clearance.
- Suitable for otologic and middle ear surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Lempert pattern for professional ENT instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Lempert Endaural Curette |
| Overall Length | 8″ |
| Working End / Blade / Jaw | Size 0 |
| Configuration | Curved |
| Primary Function | Tissue Removal and Debris Clearance |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | ENT / Otologic Surgery |
The 8″ Lempert Endaural Curette Size 0 combines an 8-inch overall length with a Size 0 working end and curved configuration.
Its defined working profile is intended for precise tissue removal in ENT applications.
Design & Function
The Lempert Endaural Curette features a curved working configuration designed to provide a specialized orientation during middle ear procedures. The working end design can assist in positioning the tip according to the requirements of the operative field.
The Size 0 working end provides a defined removal profile, while the 8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for otologic procedures requiring a curved instrument type.
Surgical Applications
The 8″ Lempert Endaural Curette Size 0 may be used for ENT and otologic surgery applications involving precise tissue removal and debris clearance. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Lempert Endaural Curette before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Lempert Endaural Curette appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Curette?
The overall length is 8 inches.
2. What is the working end design of the instrument?
It features Size 0.
3. Is this Curette curved or straight?
It features a curved configuration.
4. What is a Lempert Endaural Curette used for?
It is designed for controlled tissue removal and debris clearance in ENT applications.
5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ENT surgery?
It may be used in ENT and otologic applications where a curved and size 0 curette is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Lempert Endaural Curette be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.