
Lempert Suction Tube 6 Fr with Tucker Valve & Stylet
Direct Manufacturer Pricing • Tax Exclusive
The Lempert Suction Tube 6 Fr with Tucker Valve and Stylet is a specialized surgical suction instrument designed to assist with controlled aspiration and removal of fluids from the operative field. Its valve mechanism supports suction control, while the stylet helps maintain the tube's patency during appropriate instrument handling and maintenance.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Lempert Suction Tube 6 Fr with Tucker Valve and Stylet is a specialized surgical instrument intended for fluid aspiration in suitable surgical applications. Suction tubes help remove blood, irrigation fluid, and other fluids from the operative field, supporting visibility and access during procedures. The appropriate suction instrument depends on the anatomical site, required flow characteristics, and the surgical technique.
The 6 French (6 Fr) size designation refers to the nominal external diameter of the tube, equivalent to approximately 2 mm. Actual dimensions and internal lumen size should be confirmed with the manufacturer, as wall thickness and design influence the available suction passage.
Tucker Valve for Suction Control
The instrument incorporates a Tucker valve, which is intended to provide a means of controlling suction during use. A suction-control valve allows the operator to regulate aspiration according to the requirements of the procedure and the design of the instrument.
Controlled suction can help remove fluids while limiting unnecessary aspiration around sensitive tissues. The exact operation of the Tucker valve, including its control mechanism and compatibility with suction tubing, should be verified against the manufacturer's specifications.
Stylet for Tube Maintenance
The included stylet is designed to assist with maintaining or restoring patency when the suction tube becomes obstructed, subject to the manufacturer's instructions. Suction instruments with narrow lumens require appropriate inspection and cleaning because retained debris may interfere with fluid flow.
The stylet should be used only as directed by the manufacturer. It must not be forced through an obstruction or used in a way that could damage the tube or working end. Proper cleaning and inspection are essential before the instrument is returned to service.
Design and Clinical Usability
The Lempert suction tube combines a narrow-bore tube with a suction-control valve and a supplementary stylet. This configuration is intended to support controlled fluid removal in appropriate surgical settings. The tube's length, tip geometry, curvature, and connection design are not specified in the product title and should be confirmed with the supplier.
The instrument is intended for trained healthcare professionals. Its suitability depends on the procedure, the anatomical site, and the manufacturer's stated intended use. A 6 Fr suction tube should not be assumed appropriate for every surgical application or fluid-removal requirement.
Material and Construction
The product title does not specify the material used to manufacture this Lempert suction tube. Reusable surgical suction instruments are commonly made from surgical-grade stainless steel or other materials designed for medical use. The exact material grade, surface finish, and component construction should be confirmed with the supplier.
The valve assembly and stylet should be inspected for damage, corrosion, restricted movement, or other defects that could affect performance. Connections should also be checked for compatibility with the intended suction equipment.
Cleaning, Sterilization, and Maintenance
If designated reusable, the suction tube, Tucker valve, and stylet must be cleaned and sterilized according to the manufacturer's validated instructions. The narrow lumen requires particular attention to ensure that visible debris and residual contamination are removed. Suitable cleaning accessories and validated processes should be used where specified.
All components should be inspected after cleaning and before use. Confirm that the lumen is patent, the valve functions as intended, and the stylet is intact. Follow the manufacturer's guidance for assembly, reprocessing, and storage.
The Lempert Suction Tube 6 Fr with Tucker Valve and Stylet is a specialized option for surgical instrument inventories requiring a narrow-bore suction instrument with additional control and maintenance components. Confirm the exact dimensions, material, intended use, and reprocessing requirements before procurement.
Key Features
Lempert surgical suction tube with 6 Fr size designation
Nominal external diameter of approximately 2 mm
Tucker valve for suction control, according to the instrument design
Supplied with a stylet for tube maintenance
Designed for controlled aspiration in appropriate surgical applications
Narrow lumen for targeted fluid removal
Material and construction should be verified with the supplier
Check suction connections for compatibility with the intended equipment
Inspect tube patency, valve function, and stylet condition before use
Follow manufacturer instructions for cleaning and sterilization
Product Specifications
Specification | Details |
|---|---|
Product Name | Lempert Suction Tube |
Instrument Type | Surgical Suction Tube |
Size | 6 French (6 Fr) |
Nominal External Diameter | Approximately 2 mm |
Suction Control | Tucker valve |
Additional Component | Stylet |
Primary Function | Fluid aspiration |
Tube Length | Not specified |
Tip Configuration | Not specified |
Material | Not specified |
Connection Type | Confirm with supplier |
Intended Application | Appropriate surgical fluid aspiration |
Sterilization | Follow manufacturer instructions |
Reusability | Confirm product labeling |
Manufacturer | Not specified |
Model Number | Not specified |
Frequently Asked Questions
1. What is a Lempert Suction Tube used for?
A Lempert suction tube is a surgical instrument intended to remove fluids from the operative field in appropriate procedures. Its specific application depends on the instrument's design and the manufacturer's stated intended use.
2. What does 6 Fr mean on a suction tube?
The 6 French designation refers to a nominal external diameter of approximately 2 mm. The internal lumen diameter may be smaller and depends on the tube's wall thickness and construction.
3. What is the function of the Tucker valve?
The Tucker valve provides a means of controlling suction according to the instrument's design. Refer to the manufacturer's instructions for the correct operation and compatible suction connections.
4. Why is a stylet included with the Lempert Suction Tube?
A stylet can assist with maintaining or restoring tube patency as directed by the manufacturer. It must be handled carefully to avoid damaging the lumen or working end.
5. What material is the Lempert Suction Tube made from?
The supplied title does not specify the material. Surgical suction tubes may be manufactured from stainless steel or other medical-grade materials. Confirm the exact material with the supplier.
6. Is the Lempert Suction Tube reusable?
Reusability depends on the product's labeling and manufacturer's instructions. If designated reusable, the tube, valve, and stylet must be reprocessed according to validated procedures.
7. How should a 6 Fr suction tube be cleaned?
Follow the manufacturer's validated cleaning instructions, paying particular attention to the narrow lumen, valve assembly, and stylet. Verify patency and component integrity before sterilization and subsequent use.
8. What should buyers verify before purchasing this suction tube?
Confirm the tube length, tip design, material, valve operation, connection type, stylet dimensions, intended application, and reprocessing requirements before ordering.
