Locking Distal Humerus Medial Plates L&R 3.5mm
Direct Manufacturer Pricing • Tax Exclusive
Locking Distal Humerus Medial Plates L&R 3.5mm are orthopedic fixation implants designed for medial stabilization of distal humerus fractures. Available in left and right configurations, these plates are intended for use with a compatible 3.5mm locking screw system according to the manufacturer's specifications.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
Locking Distal Humerus Medial Plates L&R 3.5mm are orthopedic fixation implants designed to support the stabilization of fractures involving the distal humerus, particularly the medial side of the lower upper-arm bone near the elbow joint. These plates are intended for use by qualified orthopedic surgeons during fracture fixation procedures where appropriate medial support is required. Left and right configurations help accommodate the anatomical differences between the two arms.
Clinical Applications
The distal humerus is the lower portion of the humerus that forms part of the elbow joint. Fractures in this region can involve complex bone patterns and may require carefully planned internal fixation to restore alignment and support healing. A medial distal humerus plate may be used as part of a fixation construct based on the fracture pattern, bone quality, and surgical approach.
Potential applications include selected distal humerus fractures requiring medial plate support, including complex fractures where multiple plates may be used. The decision to use this implant depends on the patient's anatomy, fracture characteristics, and the treating surgeon's assessment.
Locking Plate Design
Locking plates use threaded holes that engage compatible locking screw heads to create a fixed-angle relationship between the screws and plate. This configuration can help maintain the intended fixation construct and may be beneficial in selected fractures where bone quality or fracture complexity influences implant selection.
The 3.5mm designation refers to the nominal screw system size associated with the plate design. Exact hole configuration, plate length, screw compatibility, and available sizes should be confirmed using the manufacturer's product documentation before selection.
Left and Right Configurations
The product is identified as left and right (L&R), indicating side-specific versions intended to match the corresponding anatomy. Selecting the correct configuration is important for appropriate plate positioning and surgical planning. The surgeon should verify the implant's orientation and compatibility with the intended fixation technique before use.
Material and Durability
The product title does not specify the plate material. The exact alloy, surface finish, manufacturing details, and applicable standards should therefore be verified with the supplier or manufacturer before listing or purchasing. Implant-grade materials must meet the relevant requirements for their intended medical use.
Surgical Handling and Compatibility
Locking Distal Humerus Medial Plates are intended for use by trained orthopedic professionals with the appropriate instruments and compatible fixation components. The selected screws, drill guides, drill bits, and other instruments must match the plate system and its instructions for use. Implant selection and placement should follow established surgical judgment and the manufacturer's guidance.
These plates are not universal components; compatibility should not be assumed solely from the 3.5mm designation. Proper product verification helps ensure that the plate, screws, and instrumentation are suitable for the intended procedure.
Sterilization and Storage
Sterilization requirements depend on the specific product and whether it is supplied sterile or non-sterile. Follow the manufacturer's instructions for use regarding sterilization, handling, inspection, and storage. Do not assume that an implant is sterile unless the packaging and product documentation explicitly confirm this.
Key Features
Designed for medial fixation of selected distal humerus fractures
3.5mm locking screw system designation
Left and right configurations available
Intended for orthopedic trauma and elbow fracture fixation procedures
Locking-hole design for compatible fixed-angle screw engagement
Supports fracture stabilization as part of an appropriate fixation construct
Side-specific design assists anatomical plate selection
Requires compatible screws and instrumentation
Implant material should be confirmed from manufacturer specifications
Intended for use by qualified orthopedic professionals
Product Specifications
Specification | Details |
|---|---|
Product Name | Locking Distal Humerus Medial Plates L&R |
Instrument Type | Orthopedic fixation implant |
Anatomical Location | Distal humerus, medial side |
Screw System | 3.5mm locking system designation |
Configuration | Left and right |
Application | Selected distal humerus fracture fixation |
Plate Material | Confirm with manufacturer |
Plate Lengths | Confirm available options |
Hole Configuration | Confirm with manufacturer |
Compatible Screws | Manufacturer-approved compatible 3.5mm screws |
Sterility | Confirm product packaging and documentation |
Intended Users | Qualified orthopedic surgeons and trained medical professionals |
Frequently Asked Questions
1. What are Locking Distal Humerus Medial Plates used for?
They are orthopedic implants designed to provide medial plate fixation for selected fractures of the distal humerus near the elbow joint.
2. What does 3.5mm mean in this plate system?
The 3.5mm designation refers to the nominal screw system size associated with the plate. Actual screw compatibility must be verified with the manufacturer's specifications.
3. Are left and right plates available?
Yes. The product title indicates left and right configurations intended to accommodate the anatomy of the corresponding arm.
4. Can these plates be used for all distal humerus fractures?
No. Implant selection depends on the fracture pattern, bone quality, patient anatomy, and the surgeon's treatment plan. Some fractures may require a different fixation system or a combination of plates.
5. Which screws are compatible with these plates?
Only screws specifically approved for the plate system should be used. Confirm the compatible screw types, lengths, and specifications with the manufacturer.
6. What material are the plates made from?
The product title does not specify the material. Confirm whether the plates are made from an appropriate implant-grade stainless steel or titanium alloy before purchase or publication.
7. Are the plates supplied sterile?
Sterility cannot be determined from the product title alone. Check the product packaging and manufacturer's instructions for use before handling or implantation.
8. How should these plates be sterilized?
Follow the manufacturer's validated sterilization and handling instructions. Requirements depend on the specific product and its supplied condition.