Locking Dorsal Distal Radius L Oblique Plate 2.7mm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-42511
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
Orthopedic ImplantsSKU: SP-42511AISI 420 Martensitic

Locking Dorsal Distal Radius L Oblique Plate 2.7mm

4.9 / 5.0•18 Verified OR Evaluations
$350.00$400.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $50.00 (13% OFF)

The Locking Dorsal Distal Radius L Oblique Plate 2.7mm is an orthopedic fixation implant designed for selected fractures of the distal radius near the wrist. Its oblique plate configuration supports anatomical fixation planning, while the compatible locking screw system helps establish a stable plate-screw construct.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Locking Dorsal Distal Radius L Oblique Plate 2.7mm is designed for orthopedic procedures involving fracture fixation of the distal radius, the portion of the radius bone closest to the wrist joint. Distal radius fractures can vary in complexity and may involve displacement, multiple fragments, or extension toward the articular surface. Appropriate internal fixation helps maintain the intended bone alignment during healing when selected according to the patient's anatomy and fracture pattern.

The plate's dorsal orientation and L-shaped oblique configuration are intended to support fixation planning for suitable distal radius fractures. Dorsal plating may be considered in selected cases where the fracture pattern, fragment location, or surgical approach makes dorsal fixation appropriate. The final choice of implant depends on the fracture characteristics, bone quality, anatomical requirements, and the surgeon's preferred technique.

Dorsal Plate Design and Configuration

The L oblique plate configuration provides a shaped fixation profile intended for specific distal radius applications. Its design may help the surgeon position fixation points according to the location of the fracture and the fragments requiring stabilization. Exact dimensions, contour, hole arrangement, and laterality should be confirmed using the manufacturer's product specifications.

The 2.7 mm designation identifies the stated plate or system size; it should not automatically be interpreted as the diameter of every compatible screw. Screw diameter, length, locking mechanism, and plate compatibility must be verified against the manufacturer's documentation before use.

Locking Fixation Technology

When designed for use with compatible locking screws, the plate allows screw heads to engage with corresponding threaded holes. This creates a fixed-angle relationship between the plate and screws and can help maintain the planned fixation construct. The performance of the construct depends on appropriate implant selection, screw placement, fracture reduction, bone quality, and surgical technique.

Locking fixation may be beneficial in selected fractures where maintaining fragment position is important. However, no single plate design is appropriate for every distal radius fracture. The surgeon must evaluate the fracture pattern and determine whether a dorsal L oblique plate is suitable for the intended procedure.

Orthopedic Surgical Applications

The Locking Dorsal Distal Radius L Oblique Plate 2.7mm is intended for consideration in selected distal radius fracture fixation procedures. Potential applications may include fractures requiring dorsal fixation based on fragment location or fracture configuration, subject to the implant's approved indications and the manufacturer's instructions for use.

Distal radius fracture management requires attention to wrist anatomy, joint alignment, fragment stability, and surrounding soft tissues. The implant must be positioned and secured using the appropriate surgical technique to avoid interference with adjacent anatomical structures. Qualified orthopedic surgeons should follow the manufacturer's recommendations for plate positioning, screw selection, and fixation.

Material and Durability

The product title does not specify the plate's material. The exact alloy, mechanical properties, corrosion resistance, surface finish, and biocompatibility documentation should therefore be confirmed with the manufacturer or supplier. Buyers should not assume that the plate is made from stainless steel or titanium without verified product information.

Implant integrity depends on manufacturing quality, proper handling, appropriate storage, and compliance with the intended use. Before implantation, inspect the product packaging and labeling and verify the implant's identity, dimensions, compatibility, and applicable regulatory documentation.

Handling, Sterilization, and Storage

The plate must be handled according to the manufacturer's instructions for use. Confirm whether it is supplied sterile or non-sterile before clinical use. If supplied non-sterile, it must be processed using the validated method specified by the manufacturer. Do not assume that the implant can be reused or reprocessed unless the manufacturer explicitly permits it.

Store the plate in accordance with the specified environmental and packaging requirements. Protect it from damage and contamination, and verify compatibility with all screws and instrumentation used during the procedure. Correct implant selection and adherence to surgical instructions support appropriate use in orthopedic trauma settings.

Key Features

  • Locking dorsal distal radius plate with an L oblique configuration

  • Specified 2.7 mm plate or system size

  • Designed for selected distal radius fracture fixation procedures

  • Dorsal plate configuration for appropriate surgical applications

  • Intended for use with compatible fixation screws, as specified by the manufacturer

  • Supports planned internal stabilization of suitable wrist fractures

  • Plate positioning based on fracture pattern and anatomical requirements

  • Suitable for professional orthopedic trauma applications

  • Material specifications should be verified with the supplier

  • Implant handling and sterilization must follow manufacturer instructions

Product Specifications

SpecificationDetails
Product NameLocking Dorsal Distal Radius L Oblique Plate 2.7mm
Product CategoryOrthopedic Trauma Implant
Anatomical ApplicationDistal Radius
Plate OrientationDorsal
Plate ConfigurationL Oblique
Size Designation2.7 mm
Fixation TypeLocking plate fixation, subject to system specifications
Screw CompatibilityConfirm compatible screw dimensions and type
MaterialConfirm with manufacturer
Plate DimensionsConfirm with supplier
LateralityConfirm whether left, right, or universal
Sterile StatusConfirm with supplier
PackagingConfirm with manufacturer
Intended UsersQualified orthopedic surgical professionals

Frequently Asked Questions

1. What is a locking dorsal distal radius plate used for?

A locking dorsal distal radius plate is an orthopedic implant used to stabilize selected fractures of the radius near the wrist. Its suitability depends on fracture location, configuration, and the surgeon's treatment plan.

2. What does L oblique mean in a distal radius plate?

L oblique describes the plate's general shape or configuration. The precise contour and intended anatomical positioning should be verified using the manufacturer's product documentation.

3. What does 2.7 mm mean in this plate's name?

The 2.7 mm designation identifies the stated plate or fixation system size. It does not necessarily indicate the diameter of every compatible screw. Confirm the exact dimensions with the manufacturer.

4. When is dorsal plating used for distal radius fractures?

Dorsal plating may be considered for selected fractures based on fragment location, fracture morphology, and surgical requirements. The treating orthopedic surgeon determines the appropriate fixation approach.

5. Which screws are compatible with a 2.7 mm dorsal distal radius plate?

Only screws specifically compatible with the plate's design, thread specifications, dimensions, and locking mechanism should be used. Refer to the manufacturer's compatibility chart.

6. Is the plate made from stainless steel or titanium?

The product title does not identify the material. Contact the supplier for confirmation of the alloy, implant-grade specification, and relevant technical documentation.

7. Is the locking dorsal distal radius plate supplied sterile?

The sterile status is not stated in the product title. Confirm the packaging and sterilization information with the supplier before clinical use.

8. What should be checked before purchasing this orthopedic plate?

Verify the plate dimensions, 2.7 mm system specification, left or right configuration, screw compatibility, material, intended indications, regulatory documentation, and sterile status before ordering.