Locking Proximal Medial Tibia Plates 3.5mm Titanium
Direct Manufacturer Pricing • Tax Exclusive
Locking Proximal Medial Tibia Plates 3.5mm Titanium 57 Pcs is an orthopedic fixation set designed for selected proximal tibial fracture procedures. Featuring titanium plates and compatible 3.5mm locking screws, the set provides multiple fixation options for medial tibial stabilization, subject to the specific components and manufacturer specifications.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Locking Proximal Medial Tibia Plates 3.5mm Titanium 57 Pcs set is designed for orthopedic applications involving the stabilization of selected fractures of the proximal tibia. The proximal tibia forms the upper portion of the shinbone near the knee joint, where fracture fixation may require appropriately positioned plates and screws to support bone alignment and stability.
This 57-piece set combines proximal medial tibia locking plates with compatible fixation screws, according to the supplied configuration. Its 3.5mm screw system is intended to support plate-and-screw fixation when the components are compatible with the specific implant design. The exact distribution of plates, screw sizes, plate lengths, and hole configurations should be confirmed with the manufacturer or supplier before purchase.
Purpose and Orthopedic Applications
Proximal tibial fractures can involve the tibial plateau, metaphyseal region, and adjacent portions of the tibial shaft. Depending on the fracture pattern, medial-sided fixation may be considered to support reduction and maintain alignment.
Locking proximal medial tibia plates may be used in selected tibial plateau and proximal tibial fractures when the plate's anatomical profile and fixation characteristics are appropriate. The specific application depends on the fracture configuration, bone quality, available bone stock, and the treating surgeon's assessment.
The plate provides a structural platform for securing bone fragments with compatible screws. The locking interface allows the screw head to engage with the threaded plate hole, creating a fixed-angle connection. This configuration can help maintain the intended screw-to-plate relationship within the fixation construct.
The selection of a medial tibial plate should be based on the patient's anatomy, fracture stability requirements, and the implant's approved indications. Not every proximal tibial fracture requires medial plate fixation.
Anatomical Plate Design and Fixation Options
Proximal medial tibia plates are designed to accommodate the medial aspect of the upper tibia. Their anatomical profile helps guide positioning along the intended bone surface while providing multiple screw-placement options.
Depending on the specific model, the proximal section may include several holes for fixation in the metaphyseal region, while the shaft section provides additional points for securing the plate to the tibia. Different plate lengths and hole configurations can accommodate varying fixation requirements.
The 3.5mm designation generally refers to the compatible screw system rather than the plate's thickness. Buyers should verify the plate dimensions, hole configuration, locking mechanism, and screw compatibility through the manufacturer's technical documentation.
Proper plate positioning and screw selection are essential for the intended fixation construct. Any permitted plate contouring must follow the manufacturer's instructions to avoid compromising structural integrity or locking-hole function.
Titanium Material and Its Benefits
The product title identifies the plates as titanium. Titanium is widely used in orthopedic implant manufacturing because of its favorable strength-to-weight characteristics and corrosion resistance. These properties make it an established material option for bone fixation systems.
The exact titanium grade used in this set has not been specified. Buyers should confirm whether the plates and screws use commercially pure titanium or a titanium alloy, such as Ti-6Al-4V, and request the applicable material documentation.
Material selection should also consider the implant system's mechanical requirements, manufacturing quality, surface finish, and intended clinical application. The suitability of a titanium plate depends on its specifications and proper use rather than material alone.
Locking Screws and System Compatibility
The set is described as a 3.5mm locking plate system. Compatible locking screws engage the threaded holes in the plate to create a fixed-angle connection. This design can help maintain the planned relationship between the plate and screws during fracture stabilization.
Screw diameter, length, thread design, and head configuration must match the plate manufacturer's specifications. The 3.5mm designation alone does not establish compatibility with every plate or screw system. Components from different manufacturers should not be mixed unless compatibility has been confirmed.
Before ordering, verify the number and sizes of screws included in the 57-piece set, along with the available plate lengths and hole configurations.
Benefits of a 57-Piece Orthopedic Fixation Set
A consolidated 57-piece set can simplify inventory management by grouping multiple fixation components in one package. Depending on its actual contents, the set may provide different plate configurations and compatible screws for planning selected proximal tibial fixation procedures.
For hospitals, orthopedic departments, surgical centers, and medical distributors, a complete inventory specification helps confirm that the set meets procedural and purchasing requirements. The component list, material certifications, screw compatibility, regulatory documentation, and packaging details should be reviewed before purchase.
Handling, Sterilization, and Storage
These products are orthopedic implants rather than reusable surgical instruments. Their handling, storage, and preparation must follow the manufacturer's instructions. Confirm whether the set is supplied sterile or nonsterile before use.
Sterile packaging should be inspected for damage and compromised seals. If the implants are supplied nonsterile, validated cleaning and sterilization procedures specified by the manufacturer must be followed. Proper handling helps prevent contamination and surface damage.
Implants should not be reused after removal from a patient unless reuse is explicitly permitted by the manufacturer and applicable regulations. Clinical use must be restricted to qualified professionals following the approved surgical technique and relevant healthcare requirements.
Key Features
Product Type: Locking proximal medial tibia plate set.
Set Quantity: 57 pieces, as specified in the product title.
Screw System: Designed for a compatible 3.5mm fixation system.
Material: Titanium; exact grade requires manufacturer confirmation.
Anatomical Design: Intended for medial-sided proximal tibial fixation.
Locking Mechanism: Threaded locking holes for compatible screws, where specified.
Fixation Options: Multiple plate and screw configurations, subject to actual set contents.
Orthopedic Applications: Selected proximal tibial and medial tibial plateau fracture procedures.
Material Verification: Confirm titanium grade and certification with the manufacturer.
Screw Compatibility: Requires components approved for the specific implant system.
Inventory Convenience: Multiple components supplied as a consolidated 57-piece set.
Sterilization Requirements: Follow the manufacturer's validated processing instructions.
Product Specifications Table
Specification | Details |
|---|---|
Product Name | Locking Proximal Medial Tibia Plates 3.5mm Titanium 57 Pcs |
Product Category | Orthopedic Implants |
Set Quantity | 57 pieces |
Plate Type | Locking proximal medial tibia plates |
Anatomical Location | Medial aspect of the proximal tibia |
Screw System | Compatible 3.5mm system |
Material | Titanium |
Titanium Grade | Not specified; confirm with manufacturer |
Fixation Mechanism | Locking screw-to-plate interface, where specified |
Plate Lengths | Not specified |
Number of Plate Holes | Not specified |
Screw Sizes | Not specified |
Intended Application | Selected proximal tibial fracture fixation procedures |
Sterilization Status | Confirm with supplier |
Packaging | Confirm complete component inventory |
Manufacturer | Not specified |
Frequently Asked Questions
1. What is included in the 57-piece proximal medial tibia plate set?
The product is described as a 57-piece set of 3.5mm titanium locking proximal medial tibia plates and associated fixation components. The exact number of plates, screw sizes, and component distribution should be confirmed with the supplier.
2. What are locking proximal medial tibia plates used for?
These plates are designed to stabilize selected fractures involving the upper medial portion of the tibia. Their suitability depends on the fracture pattern, anatomical requirements, and surgeon's treatment plan.
3. What are the benefits of titanium proximal tibia plates?
Titanium offers favorable strength-to-weight characteristics and corrosion resistance. The performance of an implant depends on its specific alloy, design, manufacturing quality, and appropriate clinical use.
4. What does 3.5mm mean in a locking proximal medial tibia plate set?
The 3.5mm designation generally identifies the compatible screw system. It does not necessarily indicate the plate thickness, and compatibility must be confirmed against the manufacturer's specifications.
5. Can these plates be used for tibial plateau fractures?
They may be appropriate for selected medial tibial plateau fractures when the plate design, dimensions, and approved indications meet the clinical requirements. The treating orthopedic surgeon must determine the appropriate fixation strategy.
6. Which screws are compatible with titanium proximal medial tibia plates?
Only screws that match the plate's locking-hole design and manufacturer specifications should be used. Screw diameter, length, head configuration, and thread pattern must be verified.
7. Is the 57-piece titanium plate set supplied sterile?
The product title does not specify sterility status. Confirm whether the set is supplied sterile or nonsterile and follow the manufacturer's instructions before clinical use.
8. What titanium grade is used in this plate set?
The exact titanium grade is not stated in the product title. Request the manufacturer's material specification and certification rather than assuming a particular alloy.
9. What should buyers verify before purchasing this orthopedic set?
Confirm the total component count, plate lengths, hole configurations, screw sizes, titanium grade, system compatibility, regulatory documentation, packaging, and sterilization status before ordering.