Locking Straight Plates 2.7mm with LCP Screws – Titanium

4.9 / 5.0•18 Verified OR Evaluations
$350.00$400.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $50.00 (13% OFF)

Locking Straight Plates 2.7mm with LCP Screws are designed for compatible orthopedic fixation applications requiring a straight plate profile and locking screw technology. Made from titanium, this set combines straight locking plates with compatible 2.7mm LCP screws for use by qualified surgical professionals according to the manufacturer's specifications and approved indications.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

Locking Straight Plates 2.7mm with LCP Screws are orthopedic fixation components designed for use in selected procedures requiring stabilization of bone fractures or osteotomies. The set combines straight-profile locking plates with compatible locking compression plate (LCP) screws in a 2.7mm system. The titanium construction provides a lightweight metallic option for orthopedic fixation, subject to the exact alloy and specifications confirmed by the manufacturer.

Straight locking plates are designed to sit along a suitable bone surface and provide a fixation platform for compatible screws. Their straight profile may be appropriate for selected anatomical locations and fracture configurations where the plate's dimensions, hole arrangement, and approved indications meet the requirements of the procedure. The correct plate and screw combination must be selected by the treating surgeon based on the patient's anatomy, fracture pattern, bone quality, and the manufacturer's instructions for use.

Design and Locking Mechanism

The plates feature a straight configuration with locking holes intended for use with compatible locking screws. In a locking construct, the screw head engages with the plate's locking interface to create a fixed-angle connection. This differs from conventional plate fixation, in which stability may depend more directly on compression between the plate and bone. The precise locking mechanism and available fixation options depend on the specific plate design.

The 2.7mm designation identifies the screw system size rather than confirming every plate dimension. Plate length, thickness, hole count, hole spacing, and screw lengths may vary by model. These details should be verified before ordering or using the set.

Titanium Construction

Titanium is widely used in orthopedic implant systems because of its favorable strength-to-weight characteristics and corrosion resistance. However, the product title does not identify the exact titanium grade or alloy. Buyers should confirm whether the components use a specified implant-grade titanium alloy and review the manufacturer's technical documentation before clinical use.

Orthopedic Applications

Depending on the model and its approved indications, straight locking plates in a 2.7mm system may be suitable for selected small-bone or other anatomically appropriate fixation procedures. Not every plate in this category is suitable for every bone or fracture pattern. Selection should be based on the product's intended use, anatomical fit, and the surgeon's assessment.

Screw Compatibility and Set Verification

The set is described as including LCP screws intended for the locking straight plates. Before use, confirm that the screw diameter, thread design, head-locking interface, lengths, and material specifications match the plates. Components from different systems should not be mixed unless compatibility is explicitly confirmed by the manufacturer.

The product title does not specify the number of plates or screws, the available hole configurations, screw length range, or total piece count. These details should be confirmed with the supplier before purchasing.

Handling, Sterilization, and Maintenance

Reusable instruments, if included, should be cleaned, inspected, and sterilized according to their instructions for use. Implant components must be handled and prepared according to the manufacturer's validated procedures and applicable clinical protocols. Do not assume that the set is supplied sterile unless the product documentation explicitly confirms this.

Locking Straight Plates 2.7mm with LCP Screws – Titanium provide a coordinated plate-and-screw option for compatible orthopedic fixation needs. Confirming the exact dimensions, alloy, component count, and approved indications helps ensure that the selected system meets procedural and inventory requirements.

Key Features

  • Straight-profile locking plates for compatible orthopedic fixation applications

  • Designed for use with compatible 2.7mm LCP screws

  • Titanium construction; exact grade should be verified

  • Locking-hole design for compatible screw-head engagement

  • Intended for selected fracture fixation or osteotomy procedures, subject to approved indications

  • Multiple plate lengths or hole configurations may be available, depending on the model

  • Screw lengths and quantities require confirmation

  • Plate and screw compatibility should be verified before use

  • Suitable for professional orthopedic settings when used according to manufacturer instructions

  • Sterility status and preparation requirements should be confirmed before clinical use

Product Specifications

Specification

Details

Product Name

Locking Straight Plates 2.7mm with LCP Screws

Product Category

Orthopedic fixation plates and screws

Plate Design

Straight locking plate

Screw System

2.7mm LCP

Material

Titanium; exact grade not specified

Locking Mechanism

Compatible locking plate and screw interface

Plate Lengths

Not specified

Number of Holes

Not specified

Screw Lengths

Not specified

Total Piece Count

Not specified

Intended Application

Selected orthopedic fixation procedures, according to approved indications

Sterility

Not specified; verify product documentation

Reusability

Implant components and any instruments must be handled according to their respective instructions for use

Manufacturer

Not specified

Frequently Asked Questions

1. What are Locking Straight Plates 2.7mm used for?

They are designed for selected orthopedic fixation procedures where a straight locking plate and compatible 2.7mm screw system are appropriate. The exact indications depend on the specific model and its approved instructions for use.

2. What does 2.7mm mean in this product title?

The 2.7mm designation refers to the screw system size. It does not establish the plate's thickness, length, or hole spacing.

3. Are the plates made from titanium?

The product title identifies titanium as the material. The exact grade or alloy is not specified and should be confirmed through the manufacturer's documentation.

4. Are the LCP screws included?

The title indicates that LCP screws are included. The number, lengths, and specific configurations should be confirmed with the supplier.

5. Can these plates be used with any 2.7mm locking screws?

No. Screw compatibility depends on the locking interface, thread design, dimensions, and manufacturer's specifications. Use only screws confirmed to be compatible with the selected plates.

6. Are these plates suitable for every fracture?

No. Suitability depends on the anatomical location, fracture pattern, bone quality, plate dimensions, and approved indications. Selection should be made by a qualified orthopedic professional.

7. Are the plates supplied sterile?

Sterility is not established by the product title. Check the packaging and manufacturer's documentation for the supplied condition and required preparation procedures.

8. What information should be confirmed before ordering?

Confirm the plate lengths, hole counts, screw sizes and quantities, titanium grade, total set contents, manufacturer specifications, and sterility status.