6
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-30123
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-30123AISI 420 Martensitic

Lombardi Femoral Gluteus Medius Minimus Retractor

4.9 / 5.0•18 Verified OR Evaluations
$250.00$350.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $100.00 (29% OFF)
The Lombardi Femoral/Gluteus Medius Minimus Retractor is a specialized orthopedic instrument designed for controlled retraction of the gluteus medius, gluteus minimus, and related soft tissues during hip surgery. Its dedicated configuration supports surgical exposure around the proximal femur and hip joint.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Lombardi Femoral/Gluteus Medius Minimus Retractor is a specialized orthopedic surgical instrument designed to assist with controlled soft tissue retraction during hip procedures. Its dedicated working profile is intended to provide access around the femoral and gluteal region while helping maintain exposure of the operative field.

This type of retractor is particularly relevant to procedures involving the hip joint and proximal femur, where controlled displacement of muscle and soft tissue may be required. It can assist with exposure of the femoral region and surrounding anatomy during total hip arthroplasty and other orthopedic hip procedures. The exact application and placement depend on the surgical approach, patient anatomy, and surgeon's preferred technique.

The retractor is designed to engage the intended anatomical structures while providing a stable point for manual manipulation. Its configuration can help the surgical team maintain controlled tissue displacement without requiring continuous direct manipulation of the retracted tissue. Proper placement is essential, and the instrument should be positioned according to the applicable surgical technique.

The gluteus medius and gluteus minimus are important structures around the lateral aspect of the hip. During selected hip procedures, controlled retraction of these tissues may be necessary to improve visualization and access to deeper structures. A dedicated femoral and gluteal retractor can therefore form part of a specialized hip surgery instrument set.

The Lombardi Femoral/Gluteus Medius Minimus Retractor may be used alongside other orthopedic retractors selected for acetabular exposure, femoral exposure, soft tissue management, or other stages of hip surgery. Using different retractor profiles allows the surgical team to select an instrument that corresponds with the required anatomical exposure.

Instrument dimensions and working-end geometry can vary between models and manufacturers. The specific size, blade configuration, depth, and handle design should be verified before ordering or clinical use. Compatibility with a particular surgical technique should be determined by the qualified surgical team.

The instrument is manually operated and intended for professional orthopedic surgical environments. Controlled force should be applied according to established surgical technique. Excessive pressure, improper placement, or use outside the intended application should be avoided because these factors may contribute to tissue injury or instrument damage.

When designated as a reusable surgical instrument, the Lombardi retractor should be thoroughly cleaned and reprocessed after each procedure. Blood, tissue, and other contaminants should be removed according to the manufacturer's validated cleaning instructions. Particular attention should be given to the working end, contact surfaces, edges, and areas where surgical debris may accumulate.

Following cleaning, the instrument should be inspected for cracks, bending, deformation, surface damage, excessive wear, or other defects that could affect performance. Cleaning, inspection, packaging, sterilization, maintenance, and storage should follow the manufacturer's validated instructions and the healthcare facility's established sterile-processing protocol.

The Lombardi Femoral/Gluteus Medius Minimus Retractor provides a dedicated option for controlled soft tissue exposure around the hip and proximal femur. Its specialized design makes it suitable for professional orthopedic instrument systems where precise muscle and soft tissue retraction is required.

Key Features

  • Specialized Lombardi hip retractor design
  • Designed for gluteus medius and gluteus minimus retraction
  • Supports controlled femoral and soft tissue exposure
  • Suitable for orthopedic hip surgery
  • Useful during total hip arthroplasty
  • Designed for proximal femoral surgical access
  • Manual surgical operation
  • Supports controlled positioning of soft tissue
  • Suitable for professional orthopedic instrument sets
  • Reusable when specifically designated for reusable use
  • Requires proper cleaning and inspection
  • Sterilization according to validated manufacturer instructions

Product Specifications

SpecificationDetails
Product NameLombardi Femoral/Gluteus Medius Minimus Retractor
Instrument TypeHip / Soft Tissue Retractor
Primary FunctionMuscle and Soft Tissue Retraction
Target AreaFemoral and Gluteal Region
Surgical SpecialtyOrthopedic / Hip Surgery
Common ApplicationHip Surgical Exposure
Common ProcedureTotal Hip Arthroplasty
OperationManual
Working ApplicationGluteus Medius, Gluteus Minimus and Femoral Exposure
ConstructionSurgical Instrument Construction
ReusableYes, when designated for reusable use
SterilizationAccording to manufacturer-validated instructions
CompatibilityVerify according to surgical technique and instrument system

FAQs

What is a Lombardi Femoral/Gluteus Medius Minimus Retractor used for?

It is designed to assist with controlled retraction of the gluteus medius, gluteus minimus, and surrounding soft tissues during orthopedic hip procedures.

Is the Lombardi retractor used during total hip arthroplasty?

It may be used during total hip arthroplasty when its configuration is appropriate for the selected surgical approach and required exposure.

What anatomical area does this retractor expose?

The instrument is designed for soft tissue retraction around the gluteal and proximal femoral region, helping provide access to the hip operative field.

Why is dedicated gluteal retraction useful in hip surgery?

Controlled retraction can help move muscle and soft tissue away from the operative area, supporting visualization and access to deeper anatomical structures.

Is this retractor suitable for all hip procedures?

No. Suitability depends on the surgical approach, patient anatomy, instrument dimensions, and surgeon's preferred technique.

Is the Lombardi retractor reusable?

It may be reusable when specifically manufactured and designated for reusable surgical use. Reusable instruments must be cleaned, inspected, maintained, and sterilized according to validated instructions.

How should the Lombardi retractor be cleaned?

It should be cleaned according to the manufacturer's validated reprocessing instructions, with particular attention to the working end and tissue-contact surfaces.

What should be inspected before use?

The working end, blade or contact surfaces, handle, alignment, and overall condition should be checked for cracks, deformation, bending, excessive wear, or other damage.