Malis Frazier Suction Tube – Xtra Long, 12 Fr, 8″, Titanium
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-57480
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-57480AISI 420 Martensitic

8″ Malis Frazier Suction Tube 12 Fr Titanium

4.9 / 5.0•18 Verified OR Evaluations
$215.00$230.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $15.00 (7% OFF)
  • 8″ Malis Frazier Suction Tube 12 Fr Titanium designed with an extra-long configuration for controlled fluid aspiration.
  • 12 Fr working end provides a defined suction profile for neurosurgical procedures.
  • Extra-long design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and cranial surgery applications requiring an extra-long suction instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 8″ Malis Frazier Suction Tube 12 Fr Titanium is a specialized neurosurgical instrument designed for controlled aspiration of fluids from the operative field. Its extra-long 8-inch configuration provides extended reach compared with shorter suction tubes, while the 12 Fr size offers a defined specification for selecting the appropriate suction instrument for a procedure.

This model combines the named Malis Frazier configuration with titanium construction. The extended length can assist in positioning the suction tip within the operative field, supporting effective fluid removal during surgical interventions.

Key Features

  • 8-inch overall length for extended reach in surgical procedures.
  • 12 Fr size provides a defined suction profile.
  • Extra-long configuration for specialized working orientation.
  • Designed for controlled aspiration of fluids.
  • Suitable for neurosurgical applications.
  • Supports positioning of the suction tip within the operative field.
  • Specialized Malis Frazier pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade titanium construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMalis Frazier Suction Tube
Overall Length8″
Working End / Blade / Jaw12 Fr
ConfigurationExtra Long
Primary FunctionFluid Aspiration
MaterialTitanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 8″ Malis Frazier Suction Tube 12 Fr Titanium combines an 8-inch overall length with a 12 Fr working end and extra-long configuration.
Its defined working profile is intended for controlled aspiration of fluids in neurosurgical applications.

Design & Function

The Malis Frazier Suction Tube features an extra-long working configuration designed to provide a specialized orientation during fluid aspiration. The titanium construction can assist in positioning the suction tip according to the requirements of the operative field.

The 12 Fr working dimension provides a defined suction profile, while the 8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring an extra-long suction instrument.

Surgical Applications

The 8″ Malis Frazier Suction Tube 12 Fr Titanium may be used for neurosurgical and cranial surgery applications involving fluid aspiration. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the suction tube before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the suction tube appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Suction Tube?
The overall length is 8 inches.

2. What is the working end / blade or tip design of the instrument?
It features 12 Fr.

3. Is this Suction Tube curved or straight?
It features an extra-long configuration.

4. What is a Suction Tube used for?
It is designed for controlled fluid aspiration in neurosurgical applications.

5. What clinical advantage does the extra-long design provide?
The extra-long design provides a specialized working orientation for positioning the suction tip within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and cranial surgery applications where an extra-long suction tube is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Suction Tube be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.