Maryland Dissector 35cm Rota Clear Monopolar
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-40085
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-40085AISI 420 Martensitic

Maryland Dissector 35cm Rota Clear Monopolar

4.9 / 5.0•18 Verified OR Evaluations
$100.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (17% OFF)

The Maryland Dissector 35cm Rota Clear Monopolar is a laparoscopic instrument designed for tissue dissection and controlled grasping during minimally invasive procedures. Its Maryland-style jaw profile and rotating design support precise instrument positioning, while monopolar compatibility depends on the model's specifications.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Maryland Dissector 35cm Rota Clear Monopolar is a laparoscopic surgical instrument designed to assist with tissue dissection and manipulation during minimally invasive procedures. Maryland-style dissectors typically feature a slender, angled jaw profile that allows surgical professionals to separate tissue planes and handle selected structures through a laparoscopic access port. The stated 35 cm length provides reach within the operative field, while the rotating design can support adjustment of the jaw orientation during use.

Surgical Applications

Maryland dissectors are commonly used in laparoscopic procedures where controlled tissue separation, blunt dissection, or grasping is required. Depending on the instrument's approved design and intended use, applications may include selected general and abdominal laparoscopic procedures.

The angled jaw profile can help the surgeon approach tissue from different directions within the confined working space of minimally invasive surgery. The instrument should be selected according to the procedure, access-port compatibility, tissue requirements, and the manufacturer's instructions. Specific clinical applications should not be assumed without confirming the model's intended use.

Rotating Design and Instrument Control

The term "Rota" in the product title indicates a rotating configuration, but the exact rotation mechanism and range are not specified. A rotating shaft or jaw assembly can help the operator adjust the working-end orientation without repeatedly repositioning the instrument's handle. This can be useful when access angles are limited during laparoscopic surgery.

The precise handle design, jaw dimensions, shaft diameter, and rotation control should be confirmed with the supplier. These specifications affect compatibility with access ports and the instrument's suitability for particular surgical techniques.

Monopolar Functionality

The "Monopolar" designation indicates that the instrument is intended to be compatible with a monopolar electrosurgical system, subject to confirmation of the specific model. Monopolar instruments may allow electrosurgical energy to be delivered through the working end when used with compatible equipment and accessories. The exact energy functions available for this dissector are not specified by the product title.

Before use, qualified personnel should verify compatibility with the electrosurgical generator, connecting cable, and other required components. Electrical insulation should be inspected according to the manufacturer's instructions, and the instrument should not be used if damage or deterioration is suspected. Energy settings and activation technique must follow the device instructions and established clinical protocols.

Construction and Handling

The 35 cm length is intended to provide reach for laparoscopic access, but the exact shaft diameter, working length, material, and finish are not provided. The "Clear" designation may refer to a product-specific design or finish; its precise meaning should be verified with the supplier rather than assumed.

The handle and jaw mechanism should allow controlled opening, closing, and positioning according to the instrument's design. Before each use, the user should check jaw alignment, movement, rotation, insulation integrity, and electrical connections where applicable.

Cleaning, Sterilization, and Maintenance

The required cleaning, disinfection, and sterilization procedures depend on the manufacturer's instructions and whether the instrument is reusable. Reusable laparoscopic instruments may have narrow channels, moving joints, and electrical insulation that require specific inspection and reprocessing methods. Follow the validated instructions for the exact model and do not assume that every component can undergo the same sterilization cycle.

The Maryland Dissector 35cm Rota Clear Monopolar is intended for professional surgical environments where laparoscopic dissection and, where supported, monopolar electrosurgical functionality are required. Confirming its electrical compatibility, dimensions, jaw configuration, material, and processing requirements helps ensure correct selection for the intended application.

Key Features

  • Maryland-style laparoscopic dissector

  • Stated length of 35 cm

  • Designed for tissue dissection and manipulation

  • Rotating configuration indicated by the product title

  • Monopolar designation for compatible electrosurgical use

  • Angled jaw profile for access within the operative field

  • Intended for minimally invasive surgical procedures

  • Electrical compatibility must be confirmed before use

  • Insulation and jaw function should be inspected before each procedure

  • Cleaning and sterilization must follow manufacturer instructions

Product Specifications

Specification

Details

Product Name

Maryland Dissector 35cm Rota Clear Monopolar

Instrument Type

Laparoscopic dissector

Jaw Pattern

Maryland style

Overall Length

35 cm

Rotation

Rotating configuration indicated; mechanism not specified

Energy Type

Monopolar, subject to model verification

Intended Function

Tissue dissection and manipulation

Shaft Diameter

Not specified

Jaw Dimensions

Not specified

Handle Design

Not specified

Material

Not specified

Insulation

Electrical insulation requirements to be confirmed

Connector Type

Not specified

Reusability

Confirm with supplier

Sterilization Method

Follow manufacturer instructions

Intended Users

Qualified surgical professionals

Frequently Asked Questions

1. What is a Maryland Dissector used for?

A Maryland dissector is used for controlled tissue dissection and manipulation during laparoscopic procedures. Its angled jaw profile helps the surgeon work within a confined operative space.

2. What does 35 cm mean in this product title?

It indicates the stated instrument length. Confirm the manufacturer's dimensional specifications to determine whether this refers to overall length or another measurement.

3. What does Rota mean in the product name?

It suggests a rotating design that allows adjustment of the working-end orientation. The precise rotation mechanism and range should be confirmed with the supplier.

4. What does monopolar mean for this dissector?

It indicates intended compatibility with monopolar electrosurgical functionality, if supported by the specific model. The generator, cable, connector, and operating requirements must be verified before use.

5. Can this instrument be used with any electrosurgical generator?

No universal compatibility should be assumed. Confirm compatibility with the instrument manufacturer and the electrosurgical system documentation before connecting or using it.

6. What does Clear mean in the product title?

The exact meaning of "Clear" is not established by the title alone. Ask the supplier whether it refers to a particular finish, insulation feature, or product configuration.

7. Is this Maryland dissector reusable?

The title does not confirm whether the instrument is reusable. Check the manufacturer's labeling and validated reprocessing instructions before cleaning or reusing it.

8. What should be checked before purchasing this instrument?

Confirm the length measurement, shaft diameter, jaw design, rotation mechanism, monopolar compatibility, connector type, insulation specifications, material, and sterilization requirements.