Maryland Dissector 35cm Rota Clear Monopolar
Direct Manufacturer Pricing • Tax Exclusive
The Maryland Dissector 35cm Rota Clear Monopolar is a laparoscopic instrument designed for tissue dissection and controlled grasping during minimally invasive procedures. Its Maryland-style jaw profile and rotating design support precise instrument positioning, while monopolar compatibility depends on the model's specifications.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Maryland Dissector 35cm Rota Clear Monopolar is a laparoscopic surgical instrument designed to assist with tissue dissection and manipulation during minimally invasive procedures. Maryland-style dissectors typically feature a slender, angled jaw profile that allows surgical professionals to separate tissue planes and handle selected structures through a laparoscopic access port. The stated 35 cm length provides reach within the operative field, while the rotating design can support adjustment of the jaw orientation during use.
Surgical Applications
Maryland dissectors are commonly used in laparoscopic procedures where controlled tissue separation, blunt dissection, or grasping is required. Depending on the instrument's approved design and intended use, applications may include selected general and abdominal laparoscopic procedures.
The angled jaw profile can help the surgeon approach tissue from different directions within the confined working space of minimally invasive surgery. The instrument should be selected according to the procedure, access-port compatibility, tissue requirements, and the manufacturer's instructions. Specific clinical applications should not be assumed without confirming the model's intended use.
Rotating Design and Instrument Control
The term "Rota" in the product title indicates a rotating configuration, but the exact rotation mechanism and range are not specified. A rotating shaft or jaw assembly can help the operator adjust the working-end orientation without repeatedly repositioning the instrument's handle. This can be useful when access angles are limited during laparoscopic surgery.
The precise handle design, jaw dimensions, shaft diameter, and rotation control should be confirmed with the supplier. These specifications affect compatibility with access ports and the instrument's suitability for particular surgical techniques.
Monopolar Functionality
The "Monopolar" designation indicates that the instrument is intended to be compatible with a monopolar electrosurgical system, subject to confirmation of the specific model. Monopolar instruments may allow electrosurgical energy to be delivered through the working end when used with compatible equipment and accessories. The exact energy functions available for this dissector are not specified by the product title.
Before use, qualified personnel should verify compatibility with the electrosurgical generator, connecting cable, and other required components. Electrical insulation should be inspected according to the manufacturer's instructions, and the instrument should not be used if damage or deterioration is suspected. Energy settings and activation technique must follow the device instructions and established clinical protocols.
Construction and Handling
The 35 cm length is intended to provide reach for laparoscopic access, but the exact shaft diameter, working length, material, and finish are not provided. The "Clear" designation may refer to a product-specific design or finish; its precise meaning should be verified with the supplier rather than assumed.
The handle and jaw mechanism should allow controlled opening, closing, and positioning according to the instrument's design. Before each use, the user should check jaw alignment, movement, rotation, insulation integrity, and electrical connections where applicable.
Cleaning, Sterilization, and Maintenance
The required cleaning, disinfection, and sterilization procedures depend on the manufacturer's instructions and whether the instrument is reusable. Reusable laparoscopic instruments may have narrow channels, moving joints, and electrical insulation that require specific inspection and reprocessing methods. Follow the validated instructions for the exact model and do not assume that every component can undergo the same sterilization cycle.
The Maryland Dissector 35cm Rota Clear Monopolar is intended for professional surgical environments where laparoscopic dissection and, where supported, monopolar electrosurgical functionality are required. Confirming its electrical compatibility, dimensions, jaw configuration, material, and processing requirements helps ensure correct selection for the intended application.
Key Features
Maryland-style laparoscopic dissector
Stated length of 35 cm
Designed for tissue dissection and manipulation
Rotating configuration indicated by the product title
Monopolar designation for compatible electrosurgical use
Angled jaw profile for access within the operative field
Intended for minimally invasive surgical procedures
Electrical compatibility must be confirmed before use
Insulation and jaw function should be inspected before each procedure
Cleaning and sterilization must follow manufacturer instructions
Product Specifications
Specification | Details |
|---|---|
Product Name | Maryland Dissector 35cm Rota Clear Monopolar |
Instrument Type | Laparoscopic dissector |
Jaw Pattern | Maryland style |
Overall Length | 35 cm |
Rotation | Rotating configuration indicated; mechanism not specified |
Energy Type | Monopolar, subject to model verification |
Intended Function | Tissue dissection and manipulation |
Shaft Diameter | Not specified |
Jaw Dimensions | Not specified |
Handle Design | Not specified |
Material | Not specified |
Insulation | Electrical insulation requirements to be confirmed |
Connector Type | Not specified |
Reusability | Confirm with supplier |
Sterilization Method | Follow manufacturer instructions |
Intended Users | Qualified surgical professionals |
Frequently Asked Questions
1. What is a Maryland Dissector used for?
A Maryland dissector is used for controlled tissue dissection and manipulation during laparoscopic procedures. Its angled jaw profile helps the surgeon work within a confined operative space.
2. What does 35 cm mean in this product title?
It indicates the stated instrument length. Confirm the manufacturer's dimensional specifications to determine whether this refers to overall length or another measurement.
3. What does Rota mean in the product name?
It suggests a rotating design that allows adjustment of the working-end orientation. The precise rotation mechanism and range should be confirmed with the supplier.
4. What does monopolar mean for this dissector?
It indicates intended compatibility with monopolar electrosurgical functionality, if supported by the specific model. The generator, cable, connector, and operating requirements must be verified before use.
5. Can this instrument be used with any electrosurgical generator?
No universal compatibility should be assumed. Confirm compatibility with the instrument manufacturer and the electrosurgical system documentation before connecting or using it.
6. What does Clear mean in the product title?
The exact meaning of "Clear" is not established by the title alone. Ask the supplier whether it refers to a particular finish, insulation feature, or product configuration.
7. Is this Maryland dissector reusable?
The title does not confirm whether the instrument is reusable. Check the manufacturer's labeling and validated reprocessing instructions before cleaning or reusing it.
8. What should be checked before purchasing this instrument?
Confirm the length measurement, shaft diameter, jaw design, rotation mechanism, monopolar compatibility, connector type, insulation specifications, material, and sterilization requirements.