Maryland Tapered Dissector 35cm Rota Clear Monopolar
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-07076
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-07076AISI 420 Martensitic

Maryland Tapered Dissector 35cm Monopolar

4.9 / 5.0•18 Verified OR Evaluations
$100.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (17% OFF)

The Maryland Tapered Dissector 35cm Rota Clear Monopolar is designed for tissue dissection and manipulation during minimally invasive surgical procedures. Its tapered Maryland-style jaw profile and rotating configuration support controlled positioning, while monopolar use requires compatible electrosurgical equipment.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Maryland Tapered Dissector 35cm Rota Clear Monopolar is a laparoscopic surgical instrument designed to assist with tissue dissection and manipulation in minimally invasive procedures. Its tapered Maryland-style jaw profile is intended to provide controlled access when separating tissue planes and handling selected structures. The stated 35 cm length offers reach for laparoscopic access, while the rotating configuration may help the surgeon adjust the working-end orientation during use.

Surgical Applications

Maryland dissectors are commonly used in laparoscopic procedures that require controlled tissue separation, dissection, and grasping. The tapered jaw design may be useful when a narrower working profile is needed to approach tissue within a confined operative field. Suitability depends on the instrument's exact geometry, intended use, and the procedure being performed.

Depending on the manufacturer's specifications, this type of instrument may be appropriate for selected general and abdominal laparoscopic procedures. The surgical team should confirm the intended applications and select the instrument according to the tissue involved, access requirements, and established clinical protocols.

Tapered Jaw Design

The tapered configuration indicates that the working-end profile narrows toward the tip. This design can help the operator approach selected tissue planes with controlled positioning. The Maryland-style jaw geometry is commonly associated with angled working ends that support dissection and manipulation through laparoscopic access ports.

The exact tip dimensions, jaw curvature, and opening range are not specified in the product title. These details should be verified with the supplier before purchase, particularly when a specific jaw profile is required for a procedure.

Rotating Configuration and Handling

The "Rota" designation suggests a rotating design that may allow the operator to adjust the orientation of the working end without repeatedly changing the handle position. This can support maneuverability when working through a laparoscopic port. The actual rotation range, control mechanism, and shaft diameter depend on the specific model and should be confirmed with the manufacturer.

The stated length is 35 cm. Buyers should verify whether this refers to the overall instrument length or another measurement and ensure that the instrument is compatible with the intended access-port system.

Monopolar Electrosurgical Functionality

The "Monopolar" designation indicates intended compatibility with monopolar electrosurgical equipment, subject to confirmation of the exact model. Instruments designed for monopolar use may deliver electrosurgical energy through the working end when connected to a compatible generator and the required accessories.

Before use, qualified personnel should verify compatibility with the generator, cable, connector, and applicable operating instructions. Electrical insulation should be inspected according to the manufacturer's guidance. The instrument should not be used if insulation damage, defective connections, or mechanical faults are identified.

Construction and Maintenance

The product title does not specify the material, material grade, shaft diameter, or handle construction. The meaning of "Clear" is also model-specific and should be confirmed with the supplier rather than assumed to describe a particular finish or insulation property.

Cleaning, disinfection, and sterilization requirements depend on the manufacturer's validated instructions and whether the instrument is designated for reuse. Reusable laparoscopic instruments may contain narrow working areas, moving components, and electrical insulation that require particular attention during inspection and reprocessing.

The Maryland Tapered Dissector 35cm Rota Clear Monopolar is intended for professional surgical environments where controlled laparoscopic dissection and, when supported by the specific model, monopolar electrosurgical functionality are required. Confirming the dimensions, jaw design, electrical compatibility, and processing requirements helps ensure appropriate selection for the intended procedure.

Key Features

  • Maryland-style laparoscopic dissector

  • Tapered working-end profile

  • Stated length of 35 cm

  • Rotating configuration indicated by the product title

  • Monopolar designation for compatible electrosurgical use

  • Designed for tissue dissection and manipulation

  • Tapered jaw profile for controlled access to selected tissue planes

  • Intended for minimally invasive surgical procedures

  • Electrical compatibility and insulation must be verified

  • Material and shaft diameter should be confirmed with the supplier

  • Cleaning and sterilization must follow manufacturer instructions

Product Specifications

Specification

Details

Product Name

Maryland Tapered Dissector 35cm Rota Clear Monopolar

Instrument Type

Laparoscopic dissector

Jaw Pattern

Maryland style, tapered

Stated Length

35 cm

Rotation

Rotating configuration indicated; mechanism not specified

Energy Type

Monopolar, subject to model verification

Primary Function

Tissue dissection and manipulation

Tip Design

Tapered

Shaft Diameter

Not specified

Jaw Dimensions

Not specified

Material

Not specified

Material Grade

Not specified

Insulation

Confirm with supplier

Connector Type

Not specified

Reusability

Confirm with supplier

Sterilization Method

Follow manufacturer instructions

Intended Users

Qualified surgical professionals

Frequently Asked Questions

1. What is a Maryland Tapered Dissector used for?

It is designed to assist with tissue dissection and manipulation during appropriate laparoscopic procedures. The exact application depends on the instrument's design and intended use.

2. What does tapered mean in this instrument's name?

It indicates a working-end profile that narrows toward the tip. The precise shape and dimensions should be confirmed with the supplier.

3. What is the length of this dissector?

The product title specifies 35 cm. Confirm the manufacturer's dimensional information to determine whether this represents the overall length or another measurement.

4. What does Rota mean?

It suggests a rotating configuration that may allow adjustment of the working-end orientation. The exact rotation mechanism and range are model-specific.

5. What does monopolar mean for this instrument?

It indicates intended compatibility with a monopolar electrosurgical system, subject to model verification. The instrument must be used only with compatible equipment and accessories according to manufacturer instructions.

6. Can this dissector be used with any electrosurgical generator?

No universal compatibility should be assumed. Confirm the instrument's connector, electrical specifications, and compatibility with the intended generator before use.

7. What does Clear mean in the product title?

The term is not defined by the title alone. Ask the supplier whether it refers to a particular finish, insulation feature, or product configuration.

8. Is this instrument reusable?

Reusability is not established by the product title. Confirm the manufacturer's labeling and validated cleaning and sterilization instructions before reprocessing or reuse.