7″ Micro Kerrison Rongeur 2mm Pin Ejector
Direct Manufacturer Pricing • Tax Exclusive
- 7″ Micro Kerrison Rongeur 2mm Pin Ejector designed with a pin ejector configuration for delicate bone removal and excision.
- 2 mm working tip provides a defined cutting profile for neurosurgical procedures.
- Pin ejector design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and spinal surgery applications requiring a pin ejector rongeur.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7″ Micro Kerrison Rongeur 2mm Pin Ejector is a specialized neurosurgical instrument designed for delicate bone removal in neurosurgical and spinal procedures. Its fine 2mm cutting tip provides a distinct working orientation that can assist with positioning the cutting end within the operative field.
With an overall length of 7 inches and a 2mm working tip, this rongeur provides a defined cutting profile for neurosurgical applications. The pin ejector system allows for efficient debris clearance, supporting controlled manual manipulation during procedures.
Key Features
- 7-inch overall length for controlled manual handling.
- 2 mm working tip provides a defined cutting profile.
- Pin ejector configuration for specialized working orientation.
- Designed for delicate bone removal and excision.
- Suitable for neurosurgical and spinal surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Micro Kerrison pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Micro Kerrison Rongeur |
| Overall Length | 7″ |
| Working End / Blade / Jaw | 2 mm |
| Configuration | Pin Ejector |
| Primary Function | Bone Removal and Excision |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / Spinal Surgery |
The 7″ Micro Kerrison Rongeur 2mm Pin Ejector combines a 7-inch overall length with a 2 mm working tip and pin ejector configuration.
Its defined working profile is intended for delicate bone removal and excision in neurosurgical applications.
Design & Function
The Micro Kerrison Rongeur features a pin ejector working configuration designed to provide a specialized orientation during bone removal. The 2 mm cutting tip can assist in positioning the working end according to the requirements of the operative field.
The 2 mm working dimension provides a defined cutting profile, while the 7-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a pin ejector rongeur.
Surgical Applications
The 7″ Micro Kerrison Rongeur 2mm Pin Ejector may be used for neurosurgical and spinal surgery applications involving delicate bone removal and excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Micro Kerrison Rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Micro Kerrison Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Micro Kerrison Rongeur?
The overall length is 7 inches.
2. What is the working end / blade or tip design of the instrument?
It features 2 mm working tip.
3. Is this Micro Kerrison Rongeur curved or straight?
It features a pin ejector configuration.
4. What is a Micro Kerrison Rongeur used for?
It is designed for controlled bone removal and excision in neurosurgical applications.
5. What clinical advantage does the pin ejector provide?
The pin ejector provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgical surgery?
It may be used in neurosurgical and spinal surgery applications where a pin ejector rongeur is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Micro Kerrison Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.