0.4mm Mills Endarterectomy Loop
Direct Manufacturer Pricing • Tax Exclusive
- 0.4mm Mills Endarterectomy Loop designed with a fine loop configuration for controlled plaque removal.
- 0.4 mm working width provides a defined engagement profile for cardiovascular procedures.
- Fine loop design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and endarterectomy applications requiring a fine loop instrument.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 0.4mm Mills Endarterectomy Loop is a specialized cardiovascular instrument designed for the delicate removal of atherosclerotic plaque during endarterectomy procedures. Its fine loop allows controlled engagement of plaque while minimizing trauma to the arterial wall.
With an overall length of and a 0.4 mm profile, this Endarterectomy Loop provides a defined engagement profile for cardiovascular applications. The ergonomic design allows the working end to approach arterial tissue from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- for controlled manual handling.
- 0.4 mm working width provides a defined engagement profile.
- Fine loop configuration for specialized working orientation.
- Designed for controlled plaque removal.
- Suitable for cardiovascular and endarterectomy applications.
- Supports positioning of the working end within the operative field.
- Specialized Mills pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Mills Endarterectomy Loop |
| Overall Length | |
| Working End / Blade / Jaw | 0.4 mm |
| Configuration | Fine Loop |
| Primary Function | Plaque Removal |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Endarterectomy |
The 0.4mm Mills Endarterectomy Loop combines a overall length with a 0.4 mm working width and fine loop configuration.
Its defined working profile is intended for controlled plaque removal in cardiovascular applications.
Design & Function
The Mills Endarterectomy Loop features a fine loop working configuration designed to provide a specialized orientation during plaque removal. The loop design can assist in positioning the working end according to the requirements of the operative field.
The 0.4 mm working dimension provides a defined engagement profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a fine loop instrument.
Surgical Applications
The 0.4mm Mills Endarterectomy Loop may be used for cardiovascular and endarterectomy applications involving delicate plaque removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Mills Endarterectomy Loop before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Mills Endarterectomy Loop appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Endarterectomy Loop?
The overall length is .
2. What is the working end / blade or tip design of the instrument?
It features 0.4 mm working width.
3. Is this Endarterectomy Loop curved or straight?
It features a fine loop configuration.
4. What is a Mills Endarterectomy Loop used for?
It is designed for controlled plaque removal in cardiovascular applications.
5. What clinical advantage does the fine loop design provide?
The fine loop provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and endarterectomy applications where a fine loop instrument is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Mills Endarterectomy Loop be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.