10 1/2″ Panther RX Type Dissector 4mm Angled Left
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/2″ Panther RX Type Dissector designed with an angled left configuration for controlled soft tissue dissection.
- 4 mm plate tip provides a defined dissection profile for spinal procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for orthopedic and spinal surgery applications requiring an angled dissector.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/2″ Panther RX Type Dissector is a specialized orthopedic instrument designed for controlled soft tissue dissection and mobilization within minimally invasive spinal procedures. Its 90° shaft with a 4mm left-angled plate tip provides a distinct working orientation that can assist with positioning the working end within the operative field.
With an overall length of 10 1/2 inches and a 4mm plate tip, this dissector provides a defined dissection profile for spinal applications. The angled design allows the working end to approach anatomical structures from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 10 1/2-inch overall length for deep access and tactile feedback.
- 4 mm plate tip provides a defined dissection profile.
- Angled left configuration for specialized working orientation.
- Designed for controlled soft tissue dissection and mobilization.
- Suitable for minimally invasive spinal surgery applications.
- Supports positioning of the working end within the narrow surgical corridors.
- Specialized Panther RX Type pattern for professional surgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Panther RX Type Dissector |
| Overall Length | 10 1/2″ |
| Working End / Blade / Jaw | 4 mm plate tip |
| Configuration | Angled Left |
| Primary Function | Soft Tissue Dissection |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive / Spinal Surgery |
The 10 1/2″ Panther RX Type Dissector combines a 10 1/2-inch overall length with a 4 mm plate tip and angled left configuration.
Its defined working profile is intended for controlled soft tissue dissection in minimally invasive spinal applications.
Design & Function
The Panther RX Type Dissector features an angled left working configuration designed to provide a specialized orientation during spinal procedures. The plate tip design can assist in positioning the working end according to the requirements of the operative field.
The 4 mm plate tip provides a defined dissection profile, while the 10 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring an angled dissector.
Surgical Applications
The 10 1/2″ Panther RX Type Dissector may be used for orthopedic and spinal surgery applications involving soft tissue dissection and mobilization. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Panther RX Type Dissector before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Panther RX Type Dissector appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Dissector?
The overall length is 10 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features 4 mm plate tip.
3. Is this Dissector angled or straight?
It features an angled left configuration.
4. What is a Dissector used for?
It is designed for controlled soft tissue dissection in minimally invasive spinal surgery.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for spinal surgery?
It may be used in orthopedic and spinal surgery applications where an angled dissector is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Dissector be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.