
7 1/4″ MIS Pituitary Rongeur 4mm Upbite
Direct Manufacturer Pricing • Tax Exclusive
- 7 1/4″ MIS Pituitary Rongeur 4mm Upbite designed with an upbite configuration for controlled bone and tissue removal.
- 4 mm graduated jaw provides a defined cutting profile for neurosurgical procedures.
- Upbite design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and minimally invasive spine applications requiring an upbite rongeur.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7 1/4″ MIS Pituitary Rongeur 4mm Upbite is a specialized neurosurgical instrument designed for controlled bone and tissue removal in minimally invasive spine and cranial procedures. Its upbite design provides a distinct working orientation that can assist with precise upward resection while maintaining clear visibility of the operative site.
With an overall length of 7 1/4 inches and a 4 mm graduated jaw, this rongeur provides a defined cutting profile for neurosurgical applications. The ergonomic handle reduces hand fatigue during prolonged use, supporting controlled manual manipulation during procedures.
Key Features
- 7 1/4-inch overall length for controlled manual handling.
- 4 mm graduated jaw provides a defined cutting profile.
- Upbite configuration for specialized working orientation.
- Designed for controlled bone and tissue removal.
- Suitable for neurosurgical and minimally invasive spine applications.
- Supports positioning of the working end within the operative field.
- Specialized MIS pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Pituitary Rongeur |
| Overall Length | 7 1/4″ |
| Working End / Blade / Jaw | 4 mm graduated jaw |
| Configuration | Upbite |
| Primary Function | Bone and Tissue Removal |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / Minimally Invasive Spine |
The 7 1/4″ MIS Pituitary Rongeur 4mm Upbite combines a 7 1/4-inch overall length with a 4 mm graduated jaw and upbite configuration.
Its defined working profile is intended for controlled bone and tissue removal in neurosurgical applications.
Design & Function
The MIS Pituitary Rongeur features an upbite working configuration designed to provide a specialized orientation during cranial and spine procedures. The graduated jaw design can assist in positioning the working end according to the requirements of the operative field.
The 4 mm graduated jaw provides a defined cutting profile, while the 7 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a rongeur.
Surgical Applications
The 7 1/4″ MIS Pituitary Rongeur 4mm Upbite may be used for neurosurgical and minimally invasive spine applications involving controlled bone and tissue removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Pituitary Rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Pituitary Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Pituitary Rongeur?
The overall length is 7 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 4 mm graduated jaw.
3. Is this MIS Pituitary Rongeur curved or straight?
It features an upbite configuration.
4. What is a MIS Pituitary Rongeur used for?
It is designed for controlled bone and tissue removal in neurosurgical applications.
5. What clinical advantage does the upbite design provide?
The upbite design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and minimally invasive spine applications where an upbite configuration rongeur is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Pituitary Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
