MIS Tubular Retractor – Beveled Titanium 14mm x 5cm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-58426
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-58426AISI 420 Martensitic

5 cm MIS Tubular Retractor Beveled Titanium 14mm

4.9 / 5.0•18 Verified OR Evaluations
$757.00$777.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 5 cm MIS Tubular Retractor Beveled Titanium 14mm designed with a beveled configuration for controlled tissue retraction.
  • 14 mm working width provides a defined retraction profile for neurosurgical procedures.
  • Beveled design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgery and spinal surgery applications requiring a specialized retraction instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5 cm MIS Tubular Retractor Beveled Titanium 14mm is a specialized neurosurgical instrument designed for controlled, moderate-depth access during minimally invasive spinal procedures. Its beveled tip ensures smooth insertion and atraumatic tissue separation, maintaining a clear view of the operative field.

With an overall length of 5 cm and a 14 mm working width, this retractor provides a defined retraction profile for neurosurgical applications. The lightweight yet durable titanium construction allows for repeated sterilization cycles, supporting an organized surgical environment.

Key Features

  • 5 cm overall length for controlled manual handling.
  • 14 mm working width provides a defined retraction profile.
  • Beveled configuration for specialized working orientation.
  • Designed for controlled tissue separation and visibility.
  • Suitable for neurosurgical and spinal surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized MIS pattern for professional surgical instrument sets.
  • Corrosion-resistant surgical-grade titanium construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMIS Tubular Retractor
Overall Length5 cm
Working End / Blade / Jaw14 mm
ConfigurationBeveled
Primary FunctionTissue Retraction
MaterialGerman Titanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgery / Spinal Surgery

The 5 cm MIS Tubular Retractor Beveled Titanium 14mm combines a 5 cm overall length with a 14 mm working width and beveled configuration.
Its defined working profile is intended for controlled tissue separation in neurosurgical applications.

Design & Function

The MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during spinal procedures. The beveled tip can assist in positioning the working end according to the requirements of the operative field.

The 14 mm working width provides a defined retraction profile, while the 5 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a specialized retraction instrument.

Surgical Applications

The 5 cm MIS Tubular Retractor Beveled Titanium 14mm may be used for neurosurgery and spinal surgery applications involving tissue retraction and visibility. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this MIS Tubular Retractor?
The overall length is 5 cm.

2. What is the working end / blade or tip design of the instrument?
It features 14 mm working width.

3. Is this MIS Tubular Retractor curved or straight?
It features a beveled configuration.

4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in neurosurgical applications.

5. What clinical advantage does the beveled design provide?
The beveled tip provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgery and spinal surgery applications where a beveled retraction instrument is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.