
3 cm MIS Tubular Retractor Titanium 14mm
Direct Manufacturer Pricing • Tax Exclusive
- 3 cm MIS Tubular Retractor designed with a beveled edge configuration for atraumatic tissue retraction.
- 14 mm diameter provides a defined retraction profile for orthopedic procedures.
- Beveled edge design supports a specialized working orientation within the operative field.
- Suitable for orthopedic and spinal surgery applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 3 cm MIS Tubular Retractor is a specialized orthopedic instrument designed for minimally invasive spinal procedures. Its 14 mm diameter provides a distinct working orientation that can assist with positioning the working end within the operative field.
With an overall length of 3 cm and a 14 mm diameter, this retractor provides a defined retraction profile for spinal applications. The titanium construction allows the working end to approach tissue from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 3 cm overall length for compact narrow access.
- 14 mm diameter provides a defined retraction profile.
- Beveled edge configuration for specialized working orientation.
- Designed for atraumatic tissue retraction.
- Suitable for minimally invasive spinal surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized MIS pattern for professional orthopedic instrument sets.
- Corrosion-resistant surgical-grade titanium construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 3 cm |
| Working End / Blade / Jaw | 14 mm diameter |
| Configuration | Beveled Edge |
| Primary Function | Atraumatic Tissue Retraction |
| Material | German Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Orthopedic / Spinal Surgery |
The 3 cm MIS Tubular Retractor combines a 3 cm overall length with a 14 mm diameter and beveled edge configuration.
Its defined working profile is intended for atraumatic tissue retraction in orthopedic applications.
Design & Function
The MIS Tubular Retractor features a beveled edge working configuration designed to provide a specialized orientation during spinal procedures. The titanium construction can assist in positioning the working end according to the requirements of the operative field.
The 14 mm diameter provides a defined retraction profile, while the 3 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for orthopedic procedures requiring a tubular retractor.
Surgical Applications
The 3 cm MIS Tubular Retractor may be used for orthopedic and spinal surgery applications involving atraumatic tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and bevel alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 3 cm.
2. What is the working end / blade or tip design of the instrument?
It features 14 mm diameter.
3. Is this MIS Tubular Retractor curved or straight?
It features a beveled edge configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled atraumatic tissue retraction in orthopedic applications.
5. What clinical advantage does the beveled edge provide?
The beveled edge provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for orthopedic surgery?
It may be used in orthopedic and spinal surgery applications where a beveled edge tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
