MIS Tubular Retractor – Titanium 14mm x 4cm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-58303
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-58303AISI 420 Martensitic

4 cm Titanium MIS Tubular Retractor 14mm Diameter

4.9 / 5.0•18 Verified OR Evaluations
$630.00$650.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 4 cm Titanium MIS Tubular Retractor designed with a beveled configuration for atraumatic tissue retraction.
  • 14 mm diameter provides a defined retraction profile for spinal procedures.
  • Beveled design supports a specialized working orientation within the operative field.
  • Suitable for orthopedic and spinal surgery applications requiring a tubular retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4 cm Titanium MIS Tubular Retractor is a specialized orthopedic instrument designed for narrow access during minimally invasive spinal surgery. Its beveled edges provide a smooth, atraumatic tissue retraction that can assist with positioning the working end within the operative field.

With an overall length of 4 cm and a 14 mm diameter, this retractor provides a defined retraction profile for spinal applications. The titanium construction ensures a combination of durability and lightweight handling, supporting controlled manual manipulation during procedures.

Key Features

  • 4 cm overall length for narrow access.
  • 14 mm diameter provides a defined retraction profile.
  • Beveled edges for atraumatic tissue handling.
  • Designed for efficient tissue retraction during minimally invasive procedures.
  • Suitable for orthopedic and spinal surgery applications.
  • Supports positioning of the working end within the operative field.
  • Corrosion-resistant titanium construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeTitanium MIS Tubular Retractor
Overall Length4 cm
Working End / Blade / Jaw14 mm diameter
ConfigurationBeveled
Primary FunctionTissue Retraction
MaterialGerman Titanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeOrthopedic / Spinal Surgery

The 4 cm Titanium MIS Tubular Retractor combines a 4 cm overall length with a 14 mm diameter and beveled edges.
Its defined working profile is intended for atraumatic tissue retraction in orthopedic applications.

Design & Function

The Titanium MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during spinal procedures. The beveled edges can assist in positioning the working end according to the requirements of the operative field.

The 14 mm diameter provides a defined retraction profile, while the 4 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for orthopedic procedures requiring a tubular retractor.

Surgical Applications

The 4 cm Titanium MIS Tubular Retractor may be used for orthopedic and spinal surgery applications involving atraumatic tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Titanium MIS Tubular Retractor before use, paying particular attention to the working end and beveled edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Titanium MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Retractor?
The overall length is 4 cm.

2. What is the working end / blade or tip design of the instrument?
It features 14 mm diameter.

3. Is this Retractor curved or straight?
It features a beveled configuration.

4. What is a Retractor used for?
It is designed for controlled tissue retraction in orthopedic applications.

5. What clinical advantage does the beveled design provide?
The beveled edges provide a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for orthopedic surgery?
It may be used in orthopedic and spinal surgery applications where a beveled tubular retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.