
4 cm MIS Tubular Retractor Titanium 16mm Beveled
Direct Manufacturer Pricing • Tax Exclusive
- 4 cm MIS Tubular Retractor Titanium 16mm Beveled designed with a beveled configuration for atraumatic tissue retraction.
- 16 mm beveled tip provides a defined retraction profile for minimally invasive procedures.
- Beveled design supports a specialized working orientation within the operative field.
- Suitable for minimally invasive and laparoscopic surgery applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 4 cm MIS Tubular Retractor Titanium 16mm Beveled is a specialized surgical instrument designed for atraumatic tissue retraction in minimally invasive procedures. Its beveled tip allows for smooth manipulation and effective retraction, making it ideal for narrow surgical corridors and shallow access points.
With an overall length of 4 cm and a diameter of 16 mm, this tubular retractor provides a defined retraction profile for minimally invasive surgical applications. The titanium construction ensures a balance of lightweight design and durability, supporting reliable performance through repeated sterilization cycles.
Key Features
- 4 cm overall length for enhanced maneuverability in confined spaces.
- 16 mm diameter provides a defined retraction profile.
- Beveled configuration for smooth, atraumatic tissue retraction.
- Designed for efficient tissue handling during minimally invasive procedures.
- Suitable for modular MIS systems, enhancing surgical efficiency.
- Supports positioning of the working end within the operative field.
- Corrosion-resistant titanium construction for durability.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 4 cm |
| Working End / Blade / Jaw | 16 mm Beveled Tip |
| Configuration | Beveled |
| Primary Function | Tissue Retraction |
| Material | Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Surgery |
The 4 cm MIS Tubular Retractor Titanium 16mm Beveled combines a 4 cm overall length with a 16 mm beveled tip.
Its defined working profile is intended for atraumatic tissue retraction in minimally invasive surgical applications.
Design & Function
The MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during minimally invasive procedures. The beveled tip can assist in positioning the working end according to the requirements of the operative field.
The 16 mm working end provides a defined retraction profile, while the 4 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for minimally invasive procedures requiring a tubular retractor.
Surgical Applications
The 4 cm MIS Tubular Retractor Titanium 16mm Beveled may be used for minimally invasive and laparoscopic surgery applications involving atraumatic tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and beveled tip. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 4 cm.
2. What is the working end / blade or tip design of the instrument?
It features 16 mm beveled tip.
3. Is this MIS Tubular Retractor curved or straight?
It features a beveled configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in minimally invasive surgery applications.
5. What clinical advantage does the beveled design provide?
The beveled tip provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for minimally invasive surgery?
It may be used in minimally invasive and laparoscopic applications where a beveled tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
