MIS Tubular Retractor – Titanium 18mm x 10cm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-58181
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-58181AISI 420 Martensitic

10cm MIS Tubular Retractor Titanium 18mm

4.9 / 5.0•18 Verified OR Evaluations
$832.00$852.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (2% OFF)
  • 10cm MIS Tubular Retractor designed with a tubular configuration for atraumatic tissue retraction.
  • 18 mm working width provides a defined retraction profile for spinal procedures.
  • Lightweight titanium design supports a specialized working orientation within the operative field.
  • Suitable for spinal and minimally invasive surgery applications requiring a tubular retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 10cm MIS Tubular Retractor is a specialized spinal instrument designed for deep access during minimally invasive procedures. Its 18mm working width provides a moderately narrow corridor that allows for atraumatic tissue separation, ensuring optimal surgical outcomes.

With an overall length of 10 cm and an 18 mm working width, this tubular retractor provides a defined retraction profile for spinal applications. The titanium construction ensures high strength while remaining lightweight, supporting prolonged use without compromising surgeon comfort.

Key Features

  • 10 cm overall length for deep access in minimally invasive procedures.
  • 18 mm working width provides a defined retraction profile.
  • Lightweight titanium construction for enhanced surgeon comfort.
  • Designed for atraumatic tissue separation.
  • Fully compatible with modular MIS systems.
  • Supports efficient workflow and repeated sterilization cycles.
  • Corrosion-resistant surgical-grade titanium material.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMIS Tubular Retractor
Overall Length10 cm
Working End / Blade / Jaw18 mm
ConfigurationTubular
Primary FunctionTissue Retraction
MaterialTitanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeSpinal Surgery

The 10cm MIS Tubular Retractor combines a 10 cm overall length with an 18 mm working width and a tubular configuration.
Its defined working profile is intended for tissue retraction in spinal surgery applications.

Design & Function

The MIS Tubular Retractor features a tubular working configuration designed to provide specialized orientation during spinal procedures. The lightweight titanium construction can assist in positioning the working end according to the requirements of the operative field.

The 18 mm working width provides a defined retraction profile, while the 10 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a tubular retractor.

Surgical Applications

The 10cm MIS Tubular Retractor may be used for spinal and minimally invasive surgery applications involving atraumatic tissue separation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this MIS Tubular Retractor?
The overall length is 10 cm.

2. What is the working end / blade or tip design of the instrument?
It features 18 mm working width.

3. Is this MIS Tubular Retractor curved or straight?
It features a tubular configuration.

4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in spinal surgery applications.

5. What clinical advantage does the lightweight titanium construction provide?
The titanium construction provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in spinal and minimally invasive surgery applications where a tubular retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.