MIS Tubular Retractor – Titanium 18mm x 4cm Beveled
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-57662
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-57662AISI 420 Martensitic

4 cm MIS Tubular Retractor Titanium 18mm Beveled

4.9 / 5.0•18 Verified OR Evaluations
$557.00$577.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 4 cm MIS Tubular Retractor Titanium 18mm Beveled designed with a beveled configuration for controlled exposure during minimally invasive procedures.
  • 18 mm diameter provides a defined working corridor for spinal surgeries.
  • Beveled design supports a specialized working orientation within the operative field.
  • Suitable for spinal and minimally invasive surgical applications requiring a tubular retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4 cm MIS Tubular Retractor Titanium 18mm Beveled is a specialized spinal instrument designed for controlled and focused exposure during minimally invasive procedures. Its 18mm diameter provides an efficient working corridor, while the 4 cm length is ideal for superficial anatomical targets.

With a beveled distal edge, this retractor enhances visualization and approach flexibility, allowing angled access to specific structures without repositioning the entire assembly. This feature supports precise manipulation within the operative field.

Key Features

  • 4 cm overall length for optimal exposure in minimally invasive procedures.
  • 18 mm diameter provides a defined working corridor.
  • Beveled configuration for enhanced visualization and access.
  • Designed for controlled exposure during spinal surgeries.
  • Suitable for minimally invasive surgical applications.
  • Supports precise positioning of the working end within the operative field.
  • Specialized titanium construction for professional surgical instrument sets.
  • Corrosion-resistant surgical-grade titanium material.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMIS Tubular Retractor
Overall Length4 cm
Working End / Blade / Jaw18 mm
ConfigurationBeveled
Primary FunctionControlled Exposure
MaterialGerman Titanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeMinimally Invasive Surgery

The 4 cm MIS Tubular Retractor Titanium 18mm Beveled combines a 4 cm overall length with an 18 mm diameter and beveled configuration.
Its defined working profile is intended for controlled exposure in minimally invasive surgical applications.

Design & Function

The MIS Tubular Retractor features a beveled working configuration designed to provide specialized orientation during spinal procedures. The beveled edge can assist in positioning the working end according to the requirements of the operative field.

The 18 mm diameter provides a defined exposure profile, while the 4 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for minimally invasive procedures requiring a tubular retractor.

Surgical Applications

The 4 cm MIS Tubular Retractor Titanium 18mm Beveled may be used for spinal and minimally invasive surgical applications involving controlled exposure. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and beveled edge. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this MIS Tubular Retractor?
The overall length is 4 cm.

2. What is the working end / blade or tip design of the instrument?
It features 18 mm diameter.

3. Is this MIS Tubular Retractor beveled or straight?
It features a beveled configuration.

4. What is a MIS Tubular Retractor used for?
It is designed for controlled exposure in minimally invasive surgery.

5. What clinical advantage does the beveled edge provide?
The beveled edge provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in spinal and minimally invasive surgical applications where a beveled tubular retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.