6 cm MIS Tubular Retractor Titanium 18mm Beveled
Direct Manufacturer Pricing • Tax Exclusive
- 6 cm MIS Tubular Retractor Titanium 18mm Beveled designed with a beveled configuration for muscle-sparing retraction.
- 18 mm internal diameter provides a defined retraction profile for minimally invasive procedures.
- Beveled design supports a specialized working orientation within the operative field.
- Suitable for minimally invasive and surgical applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 6 cm MIS Tubular Retractor Titanium 18mm Beveled is a specialized surgical instrument designed for enhanced visualization and controlled muscle-sparing retraction during minimally invasive procedures. Its angled distal design provides extended depth access, allowing for optimal positioning of the working end within the operative field.
With an overall length of 6 cm and an internal diameter of 18 mm, this tubular retractor offers a defined profile for effective tissue management. The beveled distal edge facilitates directional exposure, improving visualization of targeted structures while minimizing excessive tissue manipulation.
Key Features
- 6 cm overall length for extended depth access.
- 18 mm internal diameter provides a defined retraction profile.
- Beveled configuration for improved directional exposure.
- Designed for controlled muscle-sparing retraction.
- Suitable for minimally invasive surgical applications.
- Supports optimal visualization of anatomical structures.
- Specialized titanium construction for lightweight durability.
- Corrosion-resistant surgical-grade titanium material.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 6 cm |
| Working End / Blade / Jaw | 18 mm internal diameter |
| Configuration | Beveled |
| Primary Function | Muscle-Sparing Retraction |
| Material | German Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Surgery |
The 6 cm MIS Tubular Retractor Titanium 18mm Beveled combines a 6 cm overall length with an 18 mm internal diameter and beveled configuration.
Its defined working profile is intended for muscle-sparing retraction in minimally invasive surgical applications.
Design & Function
The MIS Tubular Retractor features a beveled working configuration designed to provide specialized orientation during minimally invasive procedures. The angled distal edge can assist in positioning the working end according to the requirements of the operative field.
The 18 mm internal diameter provides a defined retraction profile, while the 6 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for minimally invasive procedures requiring a tubular retractor.
Surgical Applications
The 6 cm MIS Tubular Retractor Titanium 18mm Beveled may be used for minimally invasive surgical applications involving muscle-sparing retraction and enhanced visualization. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and beveled edge. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 6 cm.
2. What is the working end / blade or tip design of the instrument?
It features 18 mm internal diameter.
3. Is this MIS Tubular Retractor beveled or straight?
It features a beveled configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled muscle-sparing retraction in minimally invasive surgery.
5. What clinical advantage does the beveled edge provide?
The beveled edge provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for minimally invasive surgery?
It may be used in minimally invasive and muscle-sparing retraction applications where a beveled tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.