7 cm MIS Tubular Retractor Titanium 18mm
Direct Manufacturer Pricing • Tax Exclusive
- 7 cm MIS Tubular Retractor Titanium 18mm designed with a straight configuration for precise tissue retraction.
- 18 mm internal diameter provides a defined retraction profile for spinal procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for orthopedic and spinal surgery applications requiring a straight retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7 cm MIS Tubular Retractor Titanium 18mm is a specialized orthopedic instrument designed for mid- to deep-depth minimally invasive spinal procedures. Its 18mm internal diameter provides a stable working corridor while preserving surrounding musculature. The straight distal profile ensures uniform circumferential tissue retraction, maintaining stable operative access and consistent visibility within the operative field.
With an overall length of 7 cm and an 18 mm internal diameter, this retractor provides a defined retraction profile for spinal applications. The ergonomic design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 7 cm overall length for controlled manual handling.
- 18 mm internal diameter provides a defined retraction profile.
- Straight configuration for specialized working orientation.
- Designed for precise decompression and neural element exposure.
- Suitable for minimally invasive spinal surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized MIS pattern for professional orthopedic instrument sets.
- Corrosion-resistant surgical-grade titanium construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 7 cm |
| Working End / Blade / Jaw | 18 mm internal diameter |
| Configuration | Straight |
| Primary Function | Tissue Retraction |
| Material | German Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Spinal Surgery |
The 7 cm MIS Tubular Retractor Titanium 18mm combines a 7 cm overall length with an 18 mm internal diameter and straight configuration.
Its defined working profile is intended for precise decompression and neural element exposure in minimally invasive spinal surgery applications.
Design & Function
The MIS Tubular Retractor features a straight working configuration designed to provide a specialized orientation during spinal procedures. The straight distal profile can assist in positioning the working end according to the requirements of the operative field.
The 18 mm internal diameter provides a defined retraction profile, while the 7 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for orthopedic procedures requiring a straight retractor.
Surgical Applications
The 7 cm MIS Tubular Retractor Titanium 18mm may be used for orthopedic and spinal surgery applications involving tissue retraction and exposure of neural elements. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 7 cm.
2. What is the working end / blade or tip design of the instrument?
It features 18 mm internal diameter.
3. Is this MIS Tubular Retractor curved or straight?
It features a Straight configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in minimally invasive spinal surgery applications.
5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for orthopedic surgery?
It may be used in orthopedic and spinal surgery applications where a straight retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.