MIS Tubular Retractor – Titanium 18mm x 9cm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-57701
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-57701AISI 420 Martensitic

9 cm MIS Tubular Retractor Titanium 18mm

4.9 / 5.0•18 Verified OR Evaluations
$630.00$650.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 9 cm MIS Tubular Retractor Titanium 18mm designed with a straight configuration for spinal retraction.
  • 18 mm internal diameter provides a defined retraction profile for spinal procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for spinal and minimally invasive surgery applications requiring a straight retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9 cm MIS Tubular Retractor Titanium 18mm is a specialized spinal instrument designed for deep, straight-line access in minimally invasive procedures. Its 18mm internal diameter provides a stable and symmetrical working corridor that assists with decompression, disc preparation, and instrumentation in deeper anatomical regions.

With an overall length of 9 cm and an 18 mm internal diameter, this retractor provides a defined retraction profile for spinal applications. The straight distal configuration ensures uniform circumferential exposure, maintaining consistent retraction and centered visualization within the operative field.

Key Features

  • 9 cm overall length for optimal access in deep anatomical regions.
  • 18 mm internal diameter provides a defined retraction profile.
  • Straight configuration for uniform circumferential exposure.
  • Designed for minimally invasive spinal procedures.
  • Suitable for spinal surgery applications.
  • Supports consistent visualization and retraction during procedures.
  • Specialized titanium construction for enhanced durability.
  • Corrosion-resistant surgical-grade titanium material.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMIS Tubular Retractor
Overall Length9 cm
Working End / Blade / Jaw18 mm internal diameter
ConfigurationStraight
Primary FunctionSpinal Retraction
MaterialGerman Titanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeSpinal Surgery

The 9 cm MIS Tubular Retractor Titanium 18mm combines a 9 cm overall length with an 18 mm internal diameter and straight configuration.
Its defined working profile is intended for spinal retraction in minimally invasive applications.

Design & Function

The MIS Tubular Retractor features a straight working configuration designed to provide a specialized orientation during spinal procedures. The straight distal design can assist in positioning the working end according to the requirements of the operative field.

The 18 mm internal diameter provides a defined retraction profile, while the 9 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a straight retractor.

Surgical Applications

The 9 cm MIS Tubular Retractor Titanium 18mm may be used for spinal and minimally invasive surgery applications involving decompression and disc preparation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this MIS Tubular Retractor?
The overall length is 9 cm.

2. What is the working end / blade or tip design of the instrument?
It features 18 mm internal diameter.

3. Is this MIS Tubular Retractor curved or straight?
It features a Straight configuration.

4. What is a MIS Tubular Retractor used for?
It is designed for controlled spinal retraction in minimally invasive applications.

5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in spinal and minimally invasive applications where a straight retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.