5 cm MIS Tubular Retractor Titanium 20mm Beveled
Direct Manufacturer Pricing • Tax Exclusive
- 5 cm MIS Tubular Retractor Titanium 20mm Beveled designed with a beveled configuration for directional exposure.
- 20 mm internal diameter provides a defined exposure profile for spinal procedures.
- Beveled design supports a specialized working orientation within the operative field.
- Suitable for spinal and minimally invasive surgery applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 5 cm MIS Tubular Retractor Titanium 20mm Beveled is a specialized spinal instrument designed for mid-depth minimally invasive procedures requiring directional exposure. Its 20mm internal diameter provides adequate space for instruments, while the 5cm length allows access to moderate-depth anatomy.
With a beveled distal edge, this retractor improves line-of-sight and facilitates targeted decompression or disc work, reducing tissue manipulation. The rigid tubular construction maintains stability and consistent tissue exposure during surgical interventions.
Key Features
- 5 cm overall length for access to moderate-depth anatomy.
- 20 mm internal diameter provides adequate space for surgical instruments.
- Beveled configuration for improved line-of-sight during procedures.
- Designed for targeted decompression and disc work.
- Suitable for minimally invasive spinal surgery applications.
- Supports stable positioning of the working end within the operative field.
- Specialized titanium construction for enhanced durability.
- Corrosion-resistant surgical-grade titanium material.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 5 cm |
| Working End / Blade / Jaw | 20 mm internal diameter |
| Configuration | Beveled |
| Primary Function | Directional Exposure |
| Material | German Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Spinal Surgery |
The 5 cm MIS Tubular Retractor Titanium 20mm Beveled combines a 5 cm overall length with a 20 mm internal diameter and beveled configuration.
Its defined working profile is intended for directional exposure in minimally invasive spinal surgery applications.
Design & Function
The MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during spinal procedures. The beveled distal edge can assist in positioning the working end according to the requirements of the operative field.
The 20 mm internal diameter provides a defined exposure profile, while the 5 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for minimally invasive spinal procedures requiring a tubular retractor.
Surgical Applications
The 5 cm MIS Tubular Retractor Titanium 20mm Beveled may be used for spinal and minimally invasive surgery applications involving targeted decompression and disc work. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 5 cm.
2. What is the working end / blade or tip design of the instrument?
It features 20 mm internal diameter.
3. Is this MIS Tubular Retractor curved or straight?
It features a beveled configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled directional exposure in minimally invasive spinal surgery applications.
5. What clinical advantage does the beveled design provide?
The beveled edge provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for spinal surgery?
It may be used in spinal and minimally invasive applications where a beveled tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.