8 cm MIS Tubular Retractor Titanium 22mm Beveled
Direct Manufacturer Pricing • Tax Exclusive
- 8 cm MIS Tubular Retractor Titanium 22mm Beveled designed with a beveled configuration for atraumatic tissue retraction.
- 22 mm working width provides a defined retraction profile for spinal procedures.
- Beveled design supports a specialized working orientation within the operative field.
- Suitable for minimally invasive surgery applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 cm MIS Tubular Retractor Titanium 22mm Beveled is a specialized surgical instrument designed for atraumatic tissue handling and enhanced access during minimally invasive spinal procedures. Its beveled edge promotes smooth insertion and reduces tissue disruption, allowing for effective positioning within the operative field.
With an overall length of 8 cm and a working width of 22 mm, this retractor provides a defined profile for spinal access applications. The titanium construction offers high strength with minimal weight, enhancing surgeon control during delicate procedures.
Key Features
- 8 cm overall length for extended reach in deeper spinal access.
- 22 mm working width provides a defined retraction profile.
- Beveled configuration for smooth insertion and reduced tissue disruption.
- Designed for atraumatic tissue handling during spinal procedures.
- Suitable for minimally invasive surgical applications.
- Supports positioning of the working end within the operative field.
- Specialized MIS design for professional surgical instrument sets.
- Corrosion-resistant titanium construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 8 cm |
| Working End / Blade / Jaw | 22 mm |
| Configuration | Beveled |
| Primary Function | Atraumatic Tissue Retraction |
| Material | Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Surgery |
The 8 cm MIS Tubular Retractor Titanium 22mm Beveled combines an 8 cm overall length with a 22 mm working width and beveled configuration.
Its defined working profile is intended for atraumatic tissue handling in minimally invasive surgical applications.
Design & Function
The MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during spinal procedures. The beveled edge can assist in positioning the working end according to the requirements of the operative field.
The 22 mm working width provides a defined retraction profile, while the 8 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for minimally invasive procedures requiring a tubular retractor.
Surgical Applications
The 8 cm MIS Tubular Retractor Titanium 22mm Beveled may be used for minimally invasive spinal surgery applications involving atraumatic tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and beveled edge. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 8 cm.
2. What is the working end / blade or tip design of the instrument?
It features 22 mm working width.
3. Is this MIS Tubular Retractor curved or straight?
It features a beveled configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled atraumatic tissue retraction in minimally invasive surgery applications.
5. What clinical advantage does the beveled edge provide?
The beveled edge provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for spinal surgery?
It may be used in minimally invasive and spinal surgery applications where a beveled tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.