MIS Tubular Retractor Titanium – 24mm x 3cm Beveled
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-58433
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-58433AISI 420 Martensitic

3 cm MIS Tubular Retractor Titanium 24mm Beveled

4.9 / 5.0•18 Verified OR Evaluations
$757.00$777.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 3 cm MIS Tubular Retractor Titanium 24mm Beveled designed with a beveled configuration for atraumatic tissue retraction.
  • 24 mm working width provides a defined retraction profile for neurosurgical procedures.
  • Beveled design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgery and spinal surgery applications requiring a tubular retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 3 cm MIS Tubular Retractor Titanium 24mm Beveled is a specialized neurosurgical instrument designed for atraumatic tissue retraction and enhanced visualization during minimally invasive spinal procedures. Its beveled tip ensures smooth insertion and minimizes trauma to surrounding tissues, providing excellent operative control.

With an overall length of 3 cm and a working width of 24 mm, this tubular retractor offers a defined retraction profile for spinal and neurosurgical applications. The lightweight titanium construction allows for easy handling while maintaining durability through repeated sterilization cycles.

Key Features

  • 3 cm overall length for optimal access in minimally invasive procedures.
  • 24 mm working width provides a defined retraction profile.
  • Beveled configuration for smooth insertion and atraumatic tissue handling.
  • Designed for effective tissue retraction and visualization during surgery.
  • Suitable for spinal and neurosurgical applications.
  • Supports organized workflow in modular MIS systems.
  • Corrosion-resistant surgical-grade titanium construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMIS Tubular Retractor
Overall Length3 cm
Working End / Blade / Jaw24 mm
ConfigurationBeveled
Primary FunctionTissue Retraction
MaterialGerman Titanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgery / Spinal Surgery

The 3 cm MIS Tubular Retractor Titanium 24mm Beveled combines a 3 cm overall length with a 24 mm working width and beveled configuration.
Its defined working profile is intended for effective tissue retraction in neurosurgical applications.

Design & Function

The MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during spinal procedures. The beveled tip can assist in positioning the working end according to the requirements of the operative field.

The 24 mm working width provides a defined retraction profile, while the 3 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a tubular retractor.

Surgical Applications

The 3 cm MIS Tubular Retractor Titanium 24mm Beveled may be used for neurosurgery and spinal surgery applications involving atraumatic tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and beveled tip. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this MIS Tubular Retractor?
The overall length is 3 cm.

2. What is the working end / blade or tip design of the instrument?
It features 24 mm working width.

3. Is this MIS Tubular Retractor curved or straight?
It features a beveled configuration.

4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in neurosurgery applications.

5. What clinical advantage does the beveled design provide?
The beveled design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in neurosurgery and spinal surgery applications where a beveled tubular retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.