7 cm MIS Tubular Retractor Titanium 24mm Beveled
Direct Manufacturer Pricing • Tax Exclusive
- 7 cm MIS Tubular Retractor Titanium 24mm Beveled designed with a beveled configuration for atraumatic tissue retraction.
- 24 mm diameter provides a defined retraction profile for spinal procedures.
- Beveled design supports a specialized working orientation within the operative field.
- Suitable for minimally invasive spinal surgery applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7 cm MIS Tubular Retractor Titanium 24mm Beveled is a specialized surgical instrument designed for mid-length wide access during minimally invasive spinal procedures. Its beveled edges allow for smooth insertion and atraumatic tissue retraction, ensuring patient safety and comfort.
With an overall length of 7 cm and a diameter of 24 mm, this tubular retractor provides a defined retraction profile for spinal applications. The titanium construction ensures durability while maintaining a lightweight design, facilitating efficient handling during surgical procedures.
Key Features
- 7 cm overall length for mid-length wide access.
- 24 mm diameter provides a defined retraction profile.
- Beveled edges for atraumatic tissue retraction.
- Designed for minimally invasive spinal procedures.
- Suitable for modular MIS systems.
- Supports repeated sterilization and efficient surgical workflow.
- Corrosion-resistant titanium construction.
- Lightweight design for ease of handling.
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 7 cm |
| Working End / Blade / Jaw | 24 mm diameter |
| Configuration | Beveled |
| Primary Function | Tissue Retraction |
| Material | Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Spinal Surgery |
The 7 cm MIS Tubular Retractor Titanium 24mm Beveled combines a 7 cm overall length with a 24 mm diameter and beveled configuration.
Its defined working profile is intended for tissue retraction in minimally invasive spinal applications.
Design & Function
The MIS Tubular Retractor features a beveled working configuration designed to provide a specialized orientation during spinal procedures. The beveled edges can assist in positioning the working end according to the requirements of the operative field.
The 24 mm diameter provides a defined retraction profile, while the 7 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a tubular retractor.
Surgical Applications
The 7 cm MIS Tubular Retractor Titanium 24mm Beveled may be used for minimally invasive spinal surgery applications involving tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and beveled edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 7 cm.
2. What is the working end / blade or tip design of the instrument?
It features 24 mm diameter.
3. Is this MIS Tubular Retractor curved or straight?
It features a beveled configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in minimally invasive spinal surgery.
5. What clinical advantage does the beveled design provide?
The beveled edges provide a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for spinal surgery?
It may be used in minimally invasive spinal surgery applications where a beveled tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.