3 cm MIS Tubular Retractor Titanium 26mm
Direct Manufacturer Pricing • Tax Exclusive
- 3 cm MIS Tubular Retractor Titanium 26mm designed with a straight configuration for gentle tissue retraction.
- 26 mm working width provides a defined retraction profile for minimally invasive procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for minimally invasive surgical applications requiring a tubular retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 3 cm MIS Tubular Retractor Titanium 26mm is a specialized surgical instrument designed for minimally invasive procedures requiring a wider working corridor. Its titanium construction provides strength and durability while remaining lightweight for ergonomic handling. The short length is ideal for shallow access points, and the smooth edges allow gentle tissue separation without trauma.
With an overall length of 3 cm and a 26 mm working width, this tubular retractor provides a defined retraction profile for minimally invasive surgical applications. The ergonomic design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 3 cm overall length for controlled manual handling.
- 26 mm working width provides a defined retraction profile.
- Ergonomic design for specialized working orientation.
- Designed for gentle tissue separation without trauma.
- Suitable for minimally invasive surgical applications.
- Supports organized and efficient surgical workflow.
- Specialized titanium construction for strength and durability.
- Corrosion-resistant and lightweight design.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 3 cm |
| Working End / Blade / Jaw | 26 mm |
| Configuration | Straight |
| Primary Function | Tissue Retraction |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Surgery |
The 3 cm MIS Tubular Retractor Titanium 26mm combines a 3 cm overall length with a 26 mm working width and straight configuration.
Its defined working profile is intended for gentle tissue retraction in minimally invasive surgical applications.
Design & Function
The MIS Tubular Retractor features a straight working configuration designed to provide a specialized orientation during minimally invasive procedures. The ergonomic design can assist in positioning the working end according to the requirements of the operative field.
The 26 mm working width provides a defined retraction profile, while the 3 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for minimally invasive procedures requiring a tubular retractor.
Surgical Applications
The 3 cm MIS Tubular Retractor Titanium 26mm may be used for minimally invasive surgical applications involving gentle tissue separation and retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 3 cm.
2. What is the working end / blade or tip design of the instrument?
It features 26 mm working width.
3. Is this MIS Tubular Retractor curved or straight?
It features a Straight configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled Tissue Retraction in minimally invasive surgical applications.
5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for minimally invasive surgery?
It may be used in minimally invasive surgical applications where a straight tubular retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.