MIS Tubular Retractor Titanium – 26mm x 5cm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-57866
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-57866AISI 420 Martensitic

5 cm MIS Tubular Retractor Titanium 26mm

4.9 / 5.0•18 Verified OR Evaluations
$630.00$650.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 5 cm MIS Tubular Retractor Titanium 26mm designed with a straight configuration for controlled tissue retraction.
  • 26 mm internal diameter provides a defined retraction profile for spinal procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for minimally invasive spinal surgery applications requiring a straight retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5 cm MIS Tubular Retractor Titanium 26mm is a specialized spinal instrument designed for shallow-to-mid-depth minimally invasive procedures requiring a wide working corridor. Its 26mm internal diameter accommodates larger instruments or dual-tool access, supporting efficient decompression, disc work, and instrumentation.

With an overall length of 5 cm and a 26 mm internal diameter, this retractor provides a defined retraction profile for spinal applications. The straight distal profile ensures uniform circumferential exposure while maintaining stable tissue retraction during surgical procedures.

Key Features

  • 5 cm overall length for controlled access to moderate-depth anatomy.
  • 26 mm internal diameter accommodates larger instruments or dual-tool access.
  • Straight configuration for uniform circumferential exposure.
  • Designed for efficient decompression and disc work.
  • Suitable for minimally invasive spinal surgery applications.
  • Supports stable tissue retraction during procedures.
  • Specialized titanium construction for enhanced strength and reduced weight.
  • Corrosion-resistant surgical-grade titanium material.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMIS Tubular Retractor
Overall Length5 cm
Working End / Blade / Jaw26 mm internal diameter
ConfigurationStraight
Primary FunctionTissue Retraction
MaterialGerman Titanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeMinimally Invasive Spinal Surgery

The 5 cm MIS Tubular Retractor Titanium 26mm combines a 5 cm overall length with a 26 mm internal diameter and straight configuration.
Its defined working profile is intended for tissue retraction in minimally invasive spinal surgery applications.

Design & Function

The MIS Tubular Retractor features a straight working configuration designed to provide a specialized orientation during spinal procedures. The straight distal profile can assist in positioning the working end according to the requirements of the operative field.

The 26 mm internal diameter provides a defined retraction profile, while the 5 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a straight retractor.

Surgical Applications

The 5 cm MIS Tubular Retractor Titanium 26mm may be used for minimally invasive spinal surgery applications involving tissue retraction and access to moderate-depth anatomy. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this MIS Tubular Retractor?
The overall length is 5 cm.

2. What is the working end / blade or tip design of the instrument?
It features 26 mm internal diameter.

3. Is this MIS Tubular Retractor curved or straight?
It features a Straight configuration.

4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in minimally invasive spinal surgery.

5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in minimally invasive spinal surgery applications where a straight retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.