8 cm MIS Tubular Retractor Titanium 26mm
Direct Manufacturer Pricing • Tax Exclusive
- 8 cm MIS Tubular Retractor Titanium 26mm designed with a straight configuration for controlled tissue retraction.
- 26 mm internal diameter provides a defined retraction profile for spinal procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for minimally invasive spinal surgery applications requiring a straight retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 cm MIS Tubular Retractor Titanium 26mm is a specialized spinal instrument designed for deep minimally invasive spinal procedures requiring a wide working corridor. Its 26mm internal diameter accommodates multiple instruments or larger tools, supporting decompression, disc work, and instrumentation with controlled tissue retraction.
With an overall length of 8 cm and a 26 mm internal diameter, this retractor provides a defined retraction profile for spinal applications. The straight distal profile allows for uniform circumferential exposure and stable operative visualization, supporting controlled manual manipulation during procedures.
Key Features
- 8 cm overall length for deep access to spinal anatomy.
- 26 mm internal diameter provides a wide working corridor.
- Straight configuration for uniform exposure.
- Designed for controlled tissue retraction during spinal procedures.
- Suitable for minimally invasive spinal surgery applications.
- Supports positioning of instruments within the operative field.
- Specialized titanium construction for professional surgical sets.
- Corrosion-resistant surgical-grade titanium material.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | MIS Tubular Retractor |
| Overall Length | 8 cm |
| Working End / Blade / Jaw | 26 mm internal diameter |
| Configuration | Straight |
| Primary Function | Tissue Retraction |
| Material | Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Minimally Invasive Spinal Surgery |
The 8 cm MIS Tubular Retractor Titanium 26mm combines an 8 cm overall length with a 26 mm internal diameter and straight configuration.
Its defined working profile is intended for controlled tissue retraction in minimally invasive spinal applications.
Design & Function
The MIS Tubular Retractor features a straight working configuration designed to provide a specialized orientation during spinal procedures. The straight distal profile can assist in positioning the working end according to the requirements of the operative field.
The 26 mm internal diameter provides a defined retraction profile, while the 8 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a straight retractor.
Surgical Applications
The 8 cm MIS Tubular Retractor Titanium 26mm may be used for spinal and minimally invasive surgery applications involving tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the MIS Tubular Retractor before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the MIS Tubular Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this MIS Tubular Retractor?
The overall length is 8 cm.
2. What is the working end / blade or tip design of the instrument?
It features 26 mm internal diameter.
3. Is this MIS Tubular Retractor curved or straight?
It features a Straight configuration.
4. What is a MIS Tubular Retractor used for?
It is designed for controlled tissue retraction in minimally invasive spinal applications.
5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for spinal surgery?
It may be used in spinal and minimally invasive applications where a straight retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the MIS Tubular Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.