Moran Posterior Inferior Retractor
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-21454
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-21454AISI 420 Martensitic

Moran Posterior-Inferior Retractor

4.9 / 5.0•18 Verified OR Evaluations
$240.00$600.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $360.00 (60% OFF)
The Moran Posterior-Inferior Retractor is a specialized orthopedic instrument designed to assist with controlled retraction around the posterior-inferior aspect of the hip joint. Its dedicated configuration supports surgical exposure during total hip arthroplasty and other orthopedic hip procedures.
Configuration
Select an option
Select a configuration above to inspect size specifications and individual photo.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Moran Posterior-Inferior Retractor is a specialized orthopedic surgical instrument designed to assist with controlled exposure of the posterior-inferior region of the hip. It provides a dedicated means of retracting soft tissue and surrounding structures away from the operative field, helping the surgical team maintain access and visualization during hip procedures.

Posterior-inferior exposure can be important during orthopedic procedures where access around the hip joint requires controlled displacement of soft tissue. The Moran retractor may be incorporated into instrument sets for total hip arthroplasty and other procedures involving the hip joint, acetabulum, or proximal femur. The exact application and positioning depend on the surgical approach, patient anatomy, and surgeon's preferred technique.

The working end is designed to engage the intended tissue or anatomical area while the handle provides manual control over positioning. Proper placement allows the retractor to maintain the desired exposure while limiting unnecessary movement within the operative field. The amount and direction of force should be controlled according to established surgical technique.

A dedicated posterior-inferior retractor can complement other hip surgery instruments used for acetabular, femoral, anterior, posterior, or lateral exposure. Different retractor profiles allow the surgical team to select an instrument appropriate for the anatomical location and exposure required during each stage of a procedure.

The Moran Posterior-Inferior Retractor is intended for professional orthopedic surgical use. Its manual design provides direct control during positioning and tissue retraction. Depending on the specific model, dimensions and working-end geometry may vary. Overall length, blade width, depth, tip design, and handle configuration can influence the instrument's suitability for particular applications.

The retractor should be positioned carefully before controlled force is applied. Excessive pressure or inappropriate placement should be avoided because it can contribute to unnecessary tissue stress or instrument damage. The instrument should be used only for its intended purpose and according to the applicable surgical technique.

When designated for reusable surgical use, the Moran Posterior-Inferior Retractor should be thoroughly cleaned and reprocessed after each procedure. Blood, tissue, and other contaminants should be removed according to the manufacturer's validated cleaning instructions. Particular attention should be given to the working end, tissue-contact surfaces, edges, and any recessed areas where surgical debris may collect.

After cleaning, the instrument should be inspected for cracks, bending, deformation, surface damage, excessive wear, or other defects that could affect performance. Any damaged instrument should be removed from service according to the healthcare facility's procedures.

Sterilization, packaging, maintenance, and storage should follow the manufacturer's validated instructions and the healthcare facility's established sterile-processing protocol. Proper reprocessing helps maintain instrument condition and supports safe preparation for subsequent surgical procedures.

The Moran Posterior-Inferior Retractor is a practical addition to orthopedic hip surgery instrument systems where controlled posterior-inferior exposure is required. Its specialized application supports soft tissue retraction and surgical access around the hip while allowing the surgical team to select the appropriate instrument for the procedure.

Key Features

  • Moran posterior-inferior retractor design
  • Designed for controlled hip tissue retraction
  • Supports posterior-inferior surgical exposure
  • Suitable for orthopedic hip procedures
  • Useful during total hip arthroplasty
  • Assists with access around the hip joint
  • Manual operation for controlled positioning
  • Can complement other hip and acetabular retractors
  • Suitable for professional orthopedic instrument trays
  • Reusable when specifically designated for reusable use
  • Requires appropriate cleaning and inspection
  • Sterilization according to validated manufacturer instructions

Product Specifications

SpecificationDetails
Product NameMoran Posterior-Inferior Retractor
Instrument TypeHip Surgical Retractor
Primary FunctionPosterior-Inferior Tissue Retraction
Surgical SpecialtyOrthopedic / Hip Surgery
ApplicationHip Surgical Exposure
Common ProcedureTotal Hip Arthroplasty
OperationManual
Working AreaPosterior-Inferior Hip Region
ConfigurationPosterior-Inferior Retractor
ConstructionSurgical Instrument Construction
ReusableYes, when designated for reusable use
SterilizationAccording to manufacturer-validated instructions
CompatibilityVerify according to surgical technique and instrument system

FAQs

What is a Moran Posterior-Inferior Retractor used for?

It is designed to assist with controlled tissue retraction and exposure around the posterior-inferior aspect of the hip joint during orthopedic procedures.

Is the Moran Retractor used during total hip arthroplasty?

It may be used during total hip arthroplasty when its configuration is appropriate for the surgical approach and required exposure.

What area does a posterior-inferior hip retractor expose?

It is designed to assist with exposure around the posterior-inferior region of the hip joint and surrounding soft tissues.

Why is posterior-inferior retraction useful during hip surgery?

Controlled retraction can move soft tissue away from the operative field, supporting visualization and access to the hip joint and related structures.

Can the Moran Retractor be used for revision hip surgery?

It may be suitable for selected revision or reconstructive hip procedures when its dimensions and configuration meet the requirements of the surgical technique.

Is the Moran Posterior-Inferior Retractor reusable?

It may be reusable when specifically manufactured and designated for reusable surgical use. Proper cleaning, inspection, maintenance, and sterilization are required.

How should the Moran Retractor be cleaned?

It should be cleaned according to the manufacturer's validated reprocessing instructions, with particular attention to the working end and tissue-contact surfaces.

What should be inspected before use?

The working end, blade or tip, handle, alignment, and overall instrument condition should be inspected for cracks, deformation, bending, excessive wear, or other damage.