7mm Morrison Aspiration Cannula 23g Tip
Direct Manufacturer Pricing • Tax Exclusive
- 7mm Morrison Aspiration Cannula designed with a straight configuration for controlled aspiration of fluids.
- 23-gauge tip provides a defined aspiration profile for ophthalmic procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for ophthalmic and intraocular surgery applications requiring a straight aspiration cannula.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7mm Morrison Aspiration Cannula is a specialized ophthalmic instrument designed for controlled aspiration of fluids and residual material during intraocular procedures. Its 23-gauge tip provides a distinct working orientation that can assist with positioning the tip within the operative field.
With an overall length of 7mm and a 23-gauge tip, this cannula provides a defined aspiration profile for ophthalmic applications. The ergonomic design allows the working end to approach delicate ocular environments from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 7mm overall length for controlled manual handling.
- 23-gauge tip provides a defined aspiration profile.
- Straight configuration for specialized working orientation.
- Designed for controlled aspiration of fluids and residual material.
- Suitable for ophthalmic and intraocular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Morrison pattern for professional ophthalmic instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Morrison Aspiration Cannula |
| Overall Length | 7mm |
| Working End / Blade / Jaw | 23-gauge tip |
| Configuration | Straight |
| Primary Function | Aspiration of Fluids |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Ophthalmic / Intraocular Surgery |
The 7mm Morrison Aspiration Cannula combines a 7mm overall length with a 23-gauge tip and straight configuration.
Its defined working profile is intended for controlled aspiration of fluids in ophthalmic applications.
Design & Function
The Morrison Aspiration Cannula features a straight working configuration designed to provide a specialized orientation during intraocular procedures. The 23-gauge tip can assist in positioning the working end according to the requirements of the operative field.
The 23-gauge tip provides a defined aspiration profile, while the 7mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a straight aspiration cannula.
Surgical Applications
The 7mm Morrison Aspiration Cannula may be used for ophthalmic and intraocular surgery applications involving the aspiration of fluids and residual material. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Morrison Aspiration Cannula before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Morrison Aspiration Cannula appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Cannula?
The overall length is 7mm.
2. What is the working end / blade or tip design of the instrument?
It features 23-gauge tip.
3. Is this Cannula curved or straight?
It features a Straight configuration.
4. What is a Morrison Aspiration Cannula used for?
It is designed for controlled aspiration of fluids in ophthalmic applications.
5. What clinical advantage does the straight design provide?
The straight configuration provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ophthalmic surgery?
It may be used in ophthalmic and intraocular applications where a straight aspiration cannula is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Morrison Aspiration Cannula be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.