6 1/4″ Myringoplasty Knife Blades Set at 90° & 115°
Direct Manufacturer Pricing • Tax Exclusive
- 6 1/4″ Myringoplasty Knife Blades Set at 90° & 115° designed with a dual-angle configuration for tympanic membrane repair.
- Blades set at 90° and 115° provide a defined cutting profile for ENT procedures.
- Dual-angle design supports a specialized working orientation within the operative field.
- Suitable for ENT and tympanic membrane repair applications requiring a Myringoplasty Knife.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 6 1/4″ Myringoplasty Knife Blades Set at 90° & 115° is a specialized ENT instrument designed for tympanic membrane repair, graft placement, and precise incision during ear, nose, and throat procedures. Its dual-angle blade configuration provides unmatched flexibility, allowing surgeons to select the ideal cutting angle based on the specific anatomical region or procedure requirement.
With an overall length of 6 1/4 inches and blades set at 90° and 115°, this Myringoplasty Knife provides a defined cutting profile for ENT applications. The unique blade orientations are particularly effective for working around the curvature of the tympanic membrane, supporting controlled manual manipulation during procedures.
Key Features
- 6 1/4-inch overall length for controlled manual handling.
- Blades set at 90° and 115° provide a defined cutting profile.
- Dual-angle configuration for specialized working orientation.
- Designed for tympanic membrane repair and graft placement.
- Suitable for ENT applications.
- Supports positioning of the working end within the operative field.
- Specialized Myringoplasty pattern for professional ENT instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Myringoplasty Knife |
| Overall Length | 6 1/4″ |
| Working End / Blade / Jaw | Blades set at 90° and 115° |
| Configuration | Dual-angle |
| Primary Function | Tympanic Membrane Repair |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | ENT |
The 6 1/4″ Myringoplasty Knife Blades Set at 90° & 115° combines a 6 1/4-inch overall length with blades set at 90° and 115° and a dual-angle configuration.
Its defined working profile is intended for tympanic membrane repair in ENT applications.
Design & Function
The Myringoplasty Knife features a dual-angle working configuration designed to provide a specialized orientation during tympanic membrane repair. The blade design can assist in positioning the working end according to the requirements of the operative field.
The blade profiles provide a defined cutting profile, while the 6 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a specialized myringoplasty instrument.
Surgical Applications
The 6 1/4″ Myringoplasty Knife Blades Set at 90° & 115° may be used for ENT and tympanic membrane repair applications involving precise incisions and graft placements. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Myringoplasty Knife before use, paying particular attention to the working end and blade alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Myringoplasty Knife appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Myringoplasty Knife?
The overall length is 6 1/4 inches.
2. What is the working end / blade design of the instrument?
It features blades set at 90° and 115°.
3. Is this Myringoplasty Knife curved or straight?
It features a dual-angle configuration.
4. What is a Myringoplasty Knife used for?
It is designed for controlled tympanic membrane repair in ENT applications.
5. What clinical advantage does the dual-angle design provide?
The dual-angle design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ENT surgery?
It may be used in ENT and tympanic membrane repair applications where a dual-angle Myringoplasty Knife is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Myringoplasty Knife be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.