New Tracheal Retractor 6″ curved
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-50845
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-50845AISI 420 Martensitic

6″ Tracheal Retractor Curved

4.9 / 5.0•18 Verified OR Evaluations
$82.00$100.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $18.00 (18% OFF)
  • 6″ Tracheal Retractor designed with a curved configuration for atraumatic retraction and exposure of the trachea.
  • Curved profile provides a defined retraction profile for ENT procedures.
  • Curved design supports a specialized working orientation within the operative field.
  • Suitable for ENT and airway surgery applications requiring a curved retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6″ Tracheal Retractor is a specialized ENT instrument designed for atraumatic retraction and exposure of the trachea during airway and laryngotracheal procedures. Its curved profile provides a distinct working orientation that can assist with positioning the working end within the operative field.

With an overall length of 6 inches and a curved design, this retractor provides a defined retraction profile for ENT applications. The ergonomic handle allows the working end to approach the trachea from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 6-inch overall length for controlled manual handling.
  • Curved design provides a defined retraction profile.
  • Ergonomic handle for stable control during tissue retraction.
  • Designed for atraumatic retraction and exposure of the trachea.
  • Suitable for ENT and airway surgery applications.
  • Supports positioning of the working end within the operative field.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeTracheal Retractor
Overall Length6″
Working End / Blade / JawCurved profile
ConfigurationCurved
Primary FunctionAtraumatic Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Airway Surgery

The 6″ Tracheal Retractor combines a 6-inch overall length with a curved design.
Its defined working profile is intended for atraumatic retraction in ENT applications.

Design & Function

The Tracheal Retractor features a curved working configuration designed to provide a specialized orientation during airway procedures. The curved design can assist in positioning the working end according to the requirements of the operative field.

The curved profile provides a defined retraction profile, while the 6-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a curved retractor.

Surgical Applications

The 6″ Tracheal Retractor may be used for ENT and airway surgery applications involving atraumatic retraction and exposure of the trachea. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Tracheal Retractor before use, paying particular attention to the working end and handle integrity. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Tracheal Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Tracheal Retractor?
The overall length is 6 inches.

2. What is the working end / blade or tip design of the instrument?
It features a curved profile.

3. Is this Tracheal Retractor curved or straight?
It features a curved configuration.

4. What is a Tracheal Retractor used for?
It is designed for controlled atraumatic retraction in ENT applications.

5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and airway surgery applications where a curved retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Tracheal Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.