O’Reilly Dual Handle Direct Anterior Retractor
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-28640
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-28640AISI 420 Martensitic

O’Reilly Dual Handle Direct Anterior Retractor

4.9 / 5.0•18 Verified OR Evaluations
$285.00$390.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $105.00 (27% OFF)
The O’Reilly Dual Handle Direct Anterior Retractor is an orthopedic surgical instrument designed to assist with controlled tissue retraction during direct anterior hip procedures. Its dual-handle configuration provides manual control and positioning while supporting access to the anterior hip operative field.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The O’Reilly Dual Handle Direct Anterior Retractor is a specialized orthopedic instrument designed to assist surgeons with controlled soft tissue retraction and exposure during direct anterior hip procedures. Its dedicated configuration is intended to support access to the anterior aspect of the hip while providing the surgical team with direct control over retractor positioning.

Direct anterior hip surgery requires carefully controlled exposure of the hip joint and surrounding structures. A dedicated anterior retractor can help maintain access to the operative field by holding selected soft tissues away from the surgical site. The O’Reilly design provides a dual-handle configuration that allows controlled manual positioning during the procedure.

The dual handles provide practical gripping points for positioning and stabilization. This configuration can be useful when the instrument needs to be adjusted or maintained during different stages of surgical exposure. The handle arrangement also allows the surgical team to control the direction and degree of retraction according to the operative technique.

The O’Reilly Dual Handle Direct Anterior Retractor may be incorporated into orthopedic instrument sets used for total hip arthroplasty and other hip procedures performed through a direct anterior approach. Its exact use depends on the instrument dimensions, working-end geometry, patient anatomy, and surgeon's preferred surgical technique.

A dedicated anterior retractor can complement other hip surgical instruments, including acetabular retractors, femoral retractors, Hohmann retractors, and soft tissue retractors. Different retractor configurations may be selected throughout a procedure depending on the required exposure and anatomical location.

Proper positioning is important when using any surgical retractor. The working end should be placed carefully on the intended tissue or anatomical structure before controlled force is applied. Excessive or inappropriate pressure should be avoided because it can cause unnecessary tissue stress or potentially damage the instrument.

The dual-handle configuration provides direct manual control without relying on powered mechanisms. This allows the surgeon or surgical assistant to make controlled adjustments as required during the procedure. The instrument should be used only for its intended application and according to established surgical technique.

For reusable surgical instruments, appropriate cleaning and inspection are essential after use. The retractor should be cleaned according to the manufacturer's validated instructions to remove blood, tissue, and other contaminants. Attention should be given to the working end, handles, joints or connections where applicable, and other surfaces that may retain surgical debris.

Following cleaning, the instrument should be inspected for cracks, bending, deformation, surface damage, excessive wear, or other defects that could affect performance. The working end and handles should remain properly aligned and functional.

Sterilization, packaging, maintenance, and storage should follow the manufacturer's validated instructions and the healthcare facility's established sterile-processing protocol. Proper reprocessing helps maintain the instrument's condition and prepares it for subsequent surgical use.

The O’Reilly Dual Handle Direct Anterior Retractor provides a dedicated solution for controlled anterior hip exposure. Its dual-handle design supports manual positioning and controlled tissue retraction, making it a useful addition to orthopedic hip surgery instrument systems where direct anterior access is required.

Key Features

  • O’Reilly dual-handle direct anterior retractor design
  • Designed for direct anterior hip exposure
  • Supports controlled soft tissue retraction
  • Dual handles provide manual positioning and control
  • Suitable for orthopedic hip procedures
  • Useful during direct anterior total hip arthroplasty
  • Helps maintain access to the anterior operative field
  • Can complement other hip and acetabular retractors
  • Manual operation for controlled surgical handling
  • Designed for professional orthopedic surgical use
  • Reusable when specifically designated for reusable use
  • Requires appropriate cleaning, inspection, and sterilization

Product Specifications

SpecificationDetails
Product NameO’Reilly Dual Handle Direct Anterior Retractor
Instrument TypeHip Surgical Retractor
DesignDual Handle / Direct Anterior
Primary FunctionTissue Retraction and Surgical Exposure
Surgical SpecialtyOrthopedic / Hip Surgery
ApplicationDirect Anterior Hip Surgery
Common ProcedureTotal Hip Arthroplasty
OperationManual
Handle ConfigurationDual Handle
ConstructionSurgical Instrument Construction
ReusableYes, when designated for reusable use
SterilizationAccording to manufacturer-validated instructions
CompatibilityVerify according to surgical technique and instrument system

FAQs

What is an O’Reilly Dual Handle Direct Anterior Retractor used for?

It is designed to assist with controlled soft tissue retraction and exposure during direct anterior hip procedures.

Is this retractor used for direct anterior hip replacement?

It may be used during total hip arthroplasty performed through a direct anterior approach when its configuration is appropriate for the surgical technique.

What is the purpose of the dual handles?

The dual-handle configuration provides gripping points that support controlled positioning, stabilization, and adjustment during surgical exposure.

What is a direct anterior hip retractor?

A direct anterior hip retractor is an orthopedic instrument designed to assist with maintaining exposure of the hip joint and surrounding structures during procedures performed through an anterior approach.

Can this retractor be used with other hip retractors?

Yes. It can complement acetabular, femoral, Hohmann, and soft tissue retractors when different areas of the hip require exposure.

Is the O’Reilly retractor reusable?

It may be reusable when specifically manufactured and designated for reusable surgical use. Cleaning, inspection, maintenance, and sterilization should follow validated instructions.

How should the retractor be cleaned?

It should be cleaned according to the manufacturer's validated reprocessing instructions, with particular attention to the working end and handle areas.

What should be inspected before use?

The working end, handles, joints or connections where applicable, alignment, and overall surface condition should be checked for cracks, deformation, bending, excessive wear, or other damage.