Orthopedic Femoral Extractor for Nail Removal
Direct Manufacturer Pricing • Tax Exclusive
The Orthopedic Femoral Extractor is a stainless steel surgical instrument designed to assist with the extraction of compatible femoral implants, including intramedullary nails when supported by the instrument's design. Its intended use and compatibility should be confirmed against the specific implant system and manufacturer instructions.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Orthopedic Femoral Extractor is an orthopedic instrument designed to assist trained surgical professionals with the removal of compatible femoral implants. Implant extraction may be required in selected cases involving fracture healing, implant replacement, complications, or other clinical indications determined by the treating surgeon.
Described as a universal nail removal instrument, this extractor is intended to support engagement with compatible nail systems during removal. However, the term "universal" does not guarantee compatibility with every intramedullary nail or orthopedic implant. The exact connection mechanism, attachment components, dimensions, and supported implant systems should be verified with the supplier before purchase.
Design and Function
Femoral extractors are designed to connect to a compatible implant or extraction adapter so that controlled pulling force can be applied during removal. The connection must engage securely with the implant's designated extraction interface to support controlled instrument handling.
Depending on the specific design, an extraction system may require separate adapters, connecting rods, or other compatible components. The product title does not confirm which accessories are included with this instrument. Buyers should verify the complete configuration and whether additional extraction components are required.
Orthopedic Applications
Femoral extraction instruments may be used during selected orthopedic procedures involving the removal of compatible femoral intramedullary nails or other implants specifically supported by the device. The procedure and extraction method depend on the implant design, its condition, the patient's anatomy, and the manufacturer's guidance.
The instrument should be used only by appropriately trained orthopedic professionals following the relevant surgical technique. Before use, the surgical team should establish compatibility with the implant and confirm that the required extraction attachments and supporting instruments are available. The product title alone does not establish suitability for every femoral nail system or every implant-removal situation.
Stainless Steel Construction
The product title identifies stainless steel as the instrument material. The exact steel grade, surface finish, shaft dimensions, and connection design are not specified. These details should be confirmed with the supplier, particularly when material specifications and compatibility are important purchasing requirements.
A suitable extraction instrument requires sound construction and a secure connection to the intended implant interface. Visible wear, deformation, damaged threads, or a loose connection may affect performance and should be assessed before use.
Handling and Operational Considerations
Controlled engagement and appropriate force application are important during implant extraction. The extractor should be connected according to the manufacturer's instructions and used only with compatible implants and designated accessories. Improper engagement or excessive force can damage the instrument or implant and may complicate the removal procedure.
Before use, inspect the instrument's connecting interface, shaft, and other functional components for damage or wear. Confirm that the required adapters and extraction tools are available and that all components are compatible with the specific implant system.
Cleaning, Sterilization, and Maintenance
The product title does not specify whether the extractor is reusable or single-use. Confirm its designated use and processing requirements with the manufacturer. If the instrument is reusable, cleaning, inspection, and sterilization must follow the manufacturer's validated instructions and the healthcare facility's applicable protocols.
Pay particular attention to connection points, threaded interfaces, and other areas where debris may accumulate. Instruments with damaged threads, corrosion, deformation, or compromised connections should be removed from service for evaluation. Proper storage helps protect the functional interfaces and maintain the instrument's condition.
Selecting the Right Femoral Extractor
When selecting an Orthopedic Femoral Extractor, confirm the supported nail systems, connection type, required adapters, shaft dimensions, material grade, and package contents. Verify whether the instrument is intended specifically for femoral intramedullary nail removal or supports additional implant types. These checks help ensure compatibility with the intended orthopedic extraction procedure.
Key Features
Orthopedic femoral extraction instrument
Stainless steel construction as specified in the product title
Described as a universal nail removal instrument
Intended for extraction of compatible orthopedic implants
May support intramedullary nail removal when compatible
Implant connection mechanism requires verification
Additional adapters and accessories may be required
Exact dimensions and material grade are not specified
Reusable or single-use status must be confirmed
Cleaning and sterilization must follow manufacturer instructions
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Orthopedic Femoral Extractor |
| Instrument Type | Orthopedic implant extraction instrument |
| Intended Function | Removal of compatible femoral implants |
| Application | Selected nail removal procedures |
| Material | Stainless steel |
| Material Grade | Not specified |
| Implant Compatibility | Confirm with manufacturer or supplier |
| Connection Type | Not specified |
| Overall Length | Not specified |
| Included Adapters | Not specified |
| Package Quantity | Not specified |
| Reusable or Single-Use | Confirm with supplier |
| Sterilization Compatibility | Follow manufacturer instructions |
| Packaging | Confirm with supplier |
Frequently Asked Questions
1. What is an orthopedic femoral extractor used for?
It is designed to assist with the removal of compatible femoral implants during selected orthopedic procedures.
2. Can this extractor remove femoral intramedullary nails?
It may be suitable for compatible intramedullary nail systems. Confirm the implant connection and manufacturer's compatibility information before use.
3. Does universal mean it fits every nail system?
No. The term "universal" does not guarantee compatibility with every implant. Some systems require specific extraction adapters or proprietary connections.
4. What material is the femoral extractor made from?
The product title specifies stainless steel, but the exact material grade and finish are not provided.
5. Are adapters included with the extractor?
The title does not specify whether adapters or connecting components are included. Confirm the package contents with the supplier.
6. Can this instrument remove other orthopedic implants?
That depends on its design and the manufacturer's stated compatibility. Do not assume it can remove plates, screws, or other implants without confirmation.
7. Is the femoral extractor reusable?
Reusable status must be confirmed for the specific model. If reusable, follow the manufacturer's validated cleaning and sterilization instructions.
8. How should the extractor be maintained?
Inspect the shaft, connection interface, and any threaded components for damage, wear, or corrosion. Process and store the instrument according to the manufacturer's instructions.
9. What should I verify before purchasing this instrument?
Confirm compatible implant systems, connection type, required adapters, dimensions, material grade, package contents, and reusable status.
10. Who should use a femoral nail removal instrument?
It should be used by appropriately trained orthopedic surgical professionals who understand the implant system, extraction technique, and manufacturer's instructions.