Orthopedic L&R Plates with LCP Screws SS 316L 127 Pcs
Direct Manufacturer Pricing • Tax Exclusive
The Surgical Ortho Plate Set includes 4, 6, 8, 10, and 12-hole left and right orthopedic plates with LCP screws in a stated 127-piece configuration. Manufactured from SS 316L as specified in the product title, this set is intended for orthopedic fracture fixation applications when the plate designs and screw specifications are appropriate. Confirm plate profiles, screw sizes, and the complete set inventory before ordering.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Surgical Ortho 4, 6, 8, 10 and 12-Hole L&R Plates with LCP Screws is an orthopedic implant set designed for fracture fixation applications. The set is described as containing left- and right-sided plates in several hole configurations, along with locking compression plate (LCP) screws. Its stated total configuration is 127 pieces, providing a range of plate and screw options for selection according to the requirements of the intended orthopedic procedure.
The exact plate types, anatomical designs, screw quantities, and individual dimensions are not specified in the product title. These details should be verified against the manufacturer's itemized inventory before purchase or clinical use.
Plate Configurations and Selection
The set includes plates with 4, 6, 8, 10, and 12 holes, with left- and right-sided versions indicated in the product title. Different hole counts provide options for selecting plate length and screw placement according to the fracture pattern, available bone, and fixation plan. The actual working length and anatomical suitability depend on the plate design, hole spacing, and overall geometry.
Left- and right-sided plates are generally designed to correspond to the anatomy of a particular side. However, the product title does not identify the anatomical locations or specific plate profiles included in this set. Confirm these details to ensure that the selected plates are suitable for the intended application.
LCP Screws and Locking Fixation
Locking compression plate systems use compatible screws designed to engage with the plate's locking mechanism. When correctly matched and assembled, the locking interface can create a fixed-angle relationship between the screw and plate. Some plate systems also support conventional screw techniques, depending on the plate design and approved components.
Screw diameter, length, thread design, head configuration, and locking compatibility are essential selection factors. Screws should not be assumed compatible with every plate merely because they are described as LCP screws. Confirm the approved screw specifications and associated instrumentation with the manufacturer.
SS 316L Material
The product title identifies the plates and set as SS 316L. Type 316L stainless steel is a low-carbon stainless steel grade used in certain medical and orthopedic applications because of its corrosion resistance and material characteristics. Nevertheless, the specific implant-grade standard, manufacturing requirements, and material certification for this set should be verified with the supplier.
Material documentation is important for implant traceability and confirmation that the products meet the requirements of the intended clinical setting. The title alone does not establish regulatory approvals, certifications, or compatibility with other implant systems.
Orthopedic Applications
Orthopedic plates and screws are used by qualified surgeons to stabilize selected fractures when internal fixation is clinically indicated. The correct implant configuration depends on the anatomical location, fracture characteristics, bone quality, patient factors, and surgical plan. The product title does not specify the anatomical indications for these plates, so they should not be assigned to a particular bone or fracture type without supporting manufacturer information.
Appropriate plate selection, screw placement, and surgical technique are essential to the fixation strategy. The set should be used only within the manufacturer's stated intended use and applicable clinical protocols.
Inspection, Handling, and Storage
Before use, verify the itemized inventory, plate dimensions, hole configurations, screw sizes, packaging integrity, and product traceability information. Inspect plates and screws for visible damage, corrosion, deformation, or defects. Do not use components that are damaged or whose identity and compatibility cannot be confirmed.
The product title does not specify whether the implants are supplied sterile, their single-use status, or their validated sterilization requirements. Follow the manufacturer's labeling for storage, handling, and preparation. Use only approved plate-and-screw combinations and compatible instruments.
The Surgical Ortho 127-Piece Plate and LCP Screw Set may be considered for orthopedic implant inventory when its verified contents match the intended fixation requirements. Confirm the exact plate profiles, left/right configurations, screw specifications, material documentation, and packaging details before ordering.
Key Features
Orthopedic plate and LCP screw set
Stated 127-piece configuration
4, 6, 8, 10, and 12-hole plate options
Left- and right-sided plates indicated
Includes LCP screws as specified in the title
SS 316L material designation
Designed for selected orthopedic fracture fixation applications
Plate profiles and anatomical indications require confirmation
Screw dimensions and quantities are not specified
Sterility and packaging details must be verified
Product Specifications
Specification | Details |
|---|---|
Product Name | Surgical Ortho Plates with LCP Screws |
Product Category | Orthopedic implant set |
Total Set Size | 127 pieces |
Plate Hole Configurations | 4, 6, 8, 10, and 12 holes |
Plate Orientation | Left and right |
Screw Type | LCP screws |
Material | SS 316L, as stated in the title |
Plate Profiles | Not specified |
Anatomical Application | Confirm with manufacturer |
Screw Diameters | Not specified |
Screw Lengths | Not specified |
Plate Dimensions | Not specified |
Sterility | Not specified |
Single-Use Status | Confirm with manufacturer |
Storage and Handling | Follow manufacturer instructions |
Frequently Asked Questions
1. What is the Surgical Ortho Plate Set used for?
It is intended for selected orthopedic fracture fixation applications using compatible plates and LCP screws. Suitability depends on the plate designs and the requirements of the planned procedure.
2. How many pieces are included in the set?
The product title specifies a total of 127 pieces. Confirm the itemized inventory to verify the number and type of plates and screws supplied.
3. What plate sizes are included?
The stated hole configurations are 4, 6, 8, 10, and 12 holes, with left- and right-sided plates indicated. Exact lengths and anatomical profiles are not specified.
4. What does LCP mean?
LCP stands for Locking Compression Plate. It refers to a plate system designed to use compatible locking screws and, depending on the design, may support other approved fixation techniques.
5. What does SS 316L mean?
SS 316L refers to a low-carbon stainless steel grade. Confirm the applicable implant-grade standard and material documentation for this specific set.
6. Are the included LCP screws compatible with every plate?
No. Compatibility depends on the plate's locking mechanism, screw diameter, thread design, and manufacturer specifications. Use only approved combinations.
7. Are the plates supplied sterile?
The product title does not specify sterile status. Check the manufacturer's packaging and labeling before clinical use.
8. What should be confirmed before ordering this set?
Verify the complete inventory, plate profiles, left/right configurations, dimensions, screw quantities and sizes, material documentation, sterility, and manufacturer instructions.