
5″ Panther Cup Forceps 0.5mm Straight
Direct Manufacturer Pricing • Tax Exclusive
- 5″ Panther Cup Forceps designed with a straight configuration for atraumatic tissue removal.
- 0.5 mm cup size provides a defined grasping profile for ENT procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for ENT and microsurgical applications requiring a straight forceps.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 5″ Panther Cup Forceps is a specialized ENT instrument designed for ultra-fine manipulation and atraumatic removal of tissue, cerumen, or micro-debris in confined ear canal spaces. Its micro-cup design allows precise grasping and containment while minimizing trauma to delicate structures.
With an overall length of 5 inches and a 0.5 mm cup size, this forceps provides a defined grasping profile for ENT applications. The straight jaws allow for direct visibility and access, supporting accurate manipulation during intricate microsurgical procedures.
Key Features
- 5-inch overall length for controlled manual handling.
- 0.5 mm cup size provides a defined grasping profile.
- Straight configuration for specialized working orientation.
- Designed for atraumatic removal of tissue and debris.
- Suitable for ENT and microsurgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Panther pattern for professional ENT instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Panther Cup Forceps |
| Overall Length | 5″ |
| Working End / Blade / Jaw | 0.5 mm Cups |
| Configuration | Straight |
| Primary Function | Atraumatic Tissue Removal |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | ENT |
The 5″ Panther Cup Forceps combines a 5-inch overall length with a 0.5 mm cup size and straight configuration.
Its defined working profile is intended for atraumatic removal of tissue and debris in ENT applications.
Design & Function
The Panther Cup Forceps features a straight working configuration designed to provide a specialized orientation during microsurgical procedures. The straight jaw design can assist in positioning the working end according to the requirements of the operative field.
The 0.5 mm cup size provides a defined grasping profile, while the 5-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a straight instrument type.
Surgical Applications
The 5″ Panther Cup Forceps may be used for ENT and microsurgical applications involving the removal of tissue, cerumen, or micro-debris. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Panther Cup Forceps before use, paying particular attention to the working end, jaw alignment, and cup integrity. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Panther Cup Forceps appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Forceps?
The overall length is 5 inches.
2. What is the working end / cup design of the instrument?
It features 0.5 mm cups.
3. Is this Forceps curved or straight?
It features a Straight configuration.
4. What is a Panther Cup Forceps used for?
It is designed for controlled atraumatic tissue removal in ENT applications.
5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ENT surgery?
It may be used in ENT and microsurgical applications where a straight cup forceps is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Panther Cup Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
