
PHILOS Proximal Humeral Locking Plates Titanium
Direct Manufacturer Pricing • Tax Exclusive
PHILOS Proximal Humeral Locking Plates in titanium are orthopedic fixation implants designed for selected fractures of the proximal humerus. Their locking plate design supports screw-based fixation, while the titanium construction provides a lightweight implant option for appropriate fracture management.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
PHILOS Proximal Humeral Locking Plates Titanium are orthopedic implants intended for internal fixation of selected fractures involving the proximal humerus, the upper portion of the upper arm bone near the shoulder joint. The PHILOS plate design is associated with proximal humeral locking plate systems used by orthopedic surgeons to stabilize suitable fracture patterns.
The plate is positioned along the proximal humerus and secured using compatible screws according to the surgical technique and the patient's fracture characteristics. Implant selection depends on fracture configuration, bone quality, anatomical requirements, and the clinical judgment of the treating surgeon.
Locking Plate Design
Locking plates use threaded screw holes that engage with compatible locking screws, creating a fixed-angle relationship between the screws and the plate. This configuration can help maintain the planned fixation structure in appropriate clinical circumstances.
The specific hole arrangement, plate profile, available lengths, and screw compatibility vary by product model. Confirm these details with the supplier before selecting the implant for a procedure.
Titanium Construction
The product title identifies titanium as the plate material. Titanium and its medical implant alloys are used in orthopedic fixation because of their favorable strength-to-weight characteristics and corrosion resistance. However, the exact titanium grade and applicable material standard for this particular plate are not specified in the title and should be verified through the manufacturer's documentation.
Material confirmation is important when assessing implant compatibility, approved applications, and relevant surgical requirements. Do not assume a particular alloy grade without supporting product specifications.
Proximal Humerus Fracture Applications
The proximal humerus is involved in fractures that may affect the shoulder's structure and function. Depending on the fracture pattern and patient-specific factors, internal fixation may be considered to stabilize the bone and support the treatment plan.
PHILOS-style locking plates may be selected for appropriate proximal humeral fractures when indicated by the orthopedic surgeon. Not every fracture requires plate fixation, and the suitability of a particular implant depends on clinical assessment, bone quality, fracture displacement, and the intended surgical approach.
Implant Selection and Screw Compatibility
Selecting the correct plate requires confirmation of the intended side, plate size, hole configuration, and compatibility with the corresponding screws. The product title does not specify whether screws are included or identify their diameters, lengths, or quantities.
Use only compatible implants and screws approved for the specific system. Mixing components from different systems without documented compatibility may compromise the intended fixation design.
Handling and Storage
Orthopedic implants should be handled according to the manufacturer's instructions to protect their surfaces and structural integrity. Inspect packaging and product identification before use, and do not use implants with damaged packaging or visible defects. Sterility status, expiration information where applicable, and storage conditions should be verified from the supplied labeling.
The PHILOS Proximal Humeral Locking Plates Titanium are intended for professional orthopedic use. Before purchase, confirm the exact model, anatomical side, dimensions, titanium grade, screw compatibility, regulatory documentation, and supplied configuration with the manufacturer or supplier.
Key Features
PHILOS-style proximal humeral locking plate design
Intended for selected proximal humerus fractures
Titanium construction, as specified in the product title
Designed for internal orthopedic fixation
Locking screw interface, subject to the exact model
Intended for use by qualified orthopedic professionals
Plate sizes and hole configurations must be confirmed
Exact titanium grade not specified
Compatible screws and included components must be verified
Handle and store according to manufacturer instructions
Product Specifications
| Specification | Details |
|---|---|
| Product Name | PHILOS Proximal Humeral Locking Plate |
| Product Category | Orthopedic fixation implant |
| Anatomical Location | Proximal humerus |
| Plate Design | Locking plate |
| Material | Titanium; exact grade not specified |
| Plate Length | Confirm with supplier |
| Hole Configuration | Confirm with supplier |
| Anatomical Side | Confirm available left and right options |
| Compatible Screws | Confirm with manufacturer |
| Screws Included | Not specified |
| Sterility Status | Confirm product labeling |
| Intended Application | Selected proximal humerus fracture fixation |
| Packaging | Confirm with supplier |
Frequently Asked Questions
1. What are PHILOS Proximal Humeral Locking Plates used for?
They are designed for internal fixation of selected fractures involving the proximal humerus, subject to the implant's approved indications and the surgeon's assessment.
2. What does PHILOS mean in orthopedic fixation?
PHILOS refers to a proximal humeral locking plate system designation associated with fixation of fractures near the shoulder. Confirm the exact manufacturer and product specifications for the model being purchased.
3. What material are these plates made from?
The product title specifies titanium. The exact titanium grade or alloy should be confirmed through the manufacturer's documentation.
4. How does a locking plate work?
Compatible locking screws engage with threaded holes in the plate to establish a fixed-angle connection between the screw and plate. The resulting construct depends on the specific implant system and surgical technique.
5. Are these plates suitable for all proximal humerus fractures?
No. Implant selection depends on the fracture pattern, bone quality, patient factors, and clinical judgment. The treating orthopedic surgeon determines the appropriate treatment.
6. Are screws included with the plates?
The product title does not state whether screws are included. Confirm the supplied contents and compatible screw requirements with the supplier.
7. Are left and right versions available?
Availability of left- and right-sided plates is not specified. Confirm the anatomical options and exact model before ordering.
8. What plate sizes are available?
The available lengths, hole counts, and configurations are not specified. Request the manufacturer's size chart or product catalog.
9. Are the plates supplied sterile?
Sterility status is not specified. Check the product labeling and packaging information before use.
10. What should be confirmed before purchasing?
Verify the titanium grade, plate dimensions, anatomical side, hole configuration, compatible screws, included components, sterility status, and manufacturer documentation.
