
23 Fr Poole Suction Curved End 8mm Tip
Direct Manufacturer Pricing • Tax Exclusive
- 23 Fr Poole Suction designed with a curved configuration for controlled aspiration of fluids.
- 8 mm tip size provides a defined suction profile for neurosurgical procedures.
- Curved design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and aspiration applications requiring a curved suction instrument.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 23 Fr Poole Suction is a specialized neurosurgical instrument designed for controlled aspiration of fluids from the operative field. Its curved-end configuration provides a distinct working orientation that can assist with positioning the suction tip within the operative field.
With an overall length of and an 8 mm tip, this suction instrument provides a defined suction profile for neurosurgical applications. The curved design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 23 Fr overall length for controlled manual handling.
- 8 mm tip size provides a defined suction profile.
- Curved configuration for specialized working orientation.
- Designed for controlled aspiration of fluids.
- Suitable for neurosurgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Poole pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Poole Suction |
| Overall Length | 23 Fr |
| Working End / Blade / Jaw | 8 mm tip |
| Configuration | Curved |
| Primary Function | Aspiration of Fluids |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 23 Fr Poole Suction combines a 23 Fr overall length with an 8 mm tip and a curved configuration.
Its defined working profile is intended for controlled aspiration of fluids in neurosurgical applications.
Design & Function
The Poole Suction features a curved working configuration designed to provide a specialized orientation during fluid aspiration. The curved design can assist in positioning the suction tip according to the requirements of the operative field.
The 8 mm tip provides a defined suction profile, while the 23 Fr overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a curved suction instrument.
Surgical Applications
The 23 Fr Poole Suction may be used for neurosurgical and aspiration applications involving the removal of fluids from the operative field. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Poole Suction before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Poole Suction appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Poole Suction?
The overall length is 23 Fr.
2. What is the working end / blade or tip design of the instrument?
It features 8 mm tip.
3. Is this Poole Suction curved or straight?
It features a curved configuration.
4. What is a Poole Suction used for?
It is designed for controlled aspiration of fluids in neurosurgical applications.
5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the suction tip within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and aspiration applications where a curved suction instrument is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Poole Suction be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
