
Posterior Acetabular Retractor
Direct Manufacturer Pricing • Tax Exclusive
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Posterior Acetabular Retractor is a specialized orthopedic instrument designed to assist with controlled exposure of the posterior aspect of the acetabulum during hip surgery. Its dedicated configuration helps the surgical team retract selected soft tissues away from the operative field while maintaining access to the acetabular region.
Posterior acetabular exposure is an important part of orthopedic procedures involving the hip joint. A dedicated posterior retractor can help provide access around the acetabulum while allowing the surgeon or surgical assistant to maintain controlled positioning. The exact application depends on the surgical approach, patient anatomy, instrument dimensions, and the surgeon's preferred technique.
This retractor may be incorporated into instrument sets used for total hip arthroplasty, acetabular procedures, hip reconstruction, and other orthopedic operations requiring posterior exposure. It can work alongside other acetabular retractors, Hohmann retractors, femoral retractors, and soft tissue retractors to provide different points of controlled retraction throughout the procedure.
The working end is positioned at the intended anatomical location and used with controlled manual force to maintain the required exposure. Proper placement is important to achieve effective retraction while minimizing unnecessary pressure on surrounding tissues. The instrument should always be used according to established surgical technique.
A dedicated posterior acetabular retractor can provide a useful alternative to general-purpose retractors when the surgical team requires a specific working profile for the posterior acetabular region. Depending on the particular model, blade width, depth, overall length, tip configuration, and handle design can vary. These characteristics should be verified before selecting the instrument for a specific procedure.
The manual configuration provides direct control during placement and adjustment. It may be used by the surgeon or surgical assistant as part of a coordinated retraction technique. When multiple retractors are required, its posterior-focused configuration can complement other instruments selected for anterior, medial, lateral, or femoral exposure.
Excessive force should be avoided during use. The retractor should be placed carefully on the intended tissue or anatomical structure and manipulated according to the surgical technique. Improper positioning or excessive pressure can potentially cause unnecessary tissue stress or damage to the instrument.
For reusable instruments, appropriate cleaning and inspection are essential after each surgical procedure. The Posterior Acetabular Retractor should be cleaned according to the manufacturer's validated instructions to remove blood, tissue, and other contaminants. The working end, bends, contact surfaces, and handle should receive appropriate attention during reprocessing.
After cleaning, the instrument should be inspected for cracks, bending, deformation, surface damage, excessive wear, or other defects. The working end should maintain its intended shape and alignment to support proper performance.
Sterilization, packaging, maintenance, and storage should follow the manufacturer's validated instructions and the healthcare facility's established sterile-processing protocol. Proper reprocessing helps maintain instrument condition and prepares the retractor for subsequent surgical use.
The Posterior Acetabular Retractor is a practical addition to orthopedic hip surgery instrument systems requiring controlled posterior acetabular exposure. Its dedicated working configuration supports soft tissue retraction and surgical access during appropriate hip and acetabular procedures.
Key Features
- Posterior acetabular retractor design
- Designed for controlled posterior hip exposure
- Supports soft tissue retraction around the acetabulum
- Suitable for orthopedic hip procedures
- Useful during total hip arthroplasty
- Helps maintain access to the posterior acetabular region
- Manual operation for controlled positioning
- Can complement other acetabular and hip retractors
- Suitable for professional orthopedic surgical environments
- Working configuration designed for targeted exposure
- Reusable when specifically designated for reusable use
- Requires proper cleaning, inspection, and sterilization
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Posterior Acetabular Retractor |
| Instrument Type | Acetabular / Hip Retractor |
| Primary Function | Posterior Acetabular Exposure |
| Surgical Specialty | Orthopedic / Hip Surgery |
| Application | Hip and Acetabular Surgical Exposure |
| Common Procedure | Total Hip Arthroplasty |
| Operation | Manual |
| Working Area | Posterior Acetabular Region |
| Construction | Surgical Instrument Construction |
| Reusable | Yes, when designated for reusable use |
| Sterilization | According to manufacturer-validated instructions |
| Compatibility | Verify according to surgical technique and instrument system |
FAQs
What is a Posterior Acetabular Retractor used for?
It is designed to assist with controlled soft tissue retraction and exposure around the posterior aspect of the acetabulum during hip surgery.
Is this retractor used during total hip arthroplasty?
It may be used during total hip arthroplasty when its configuration is appropriate for the surgical approach and required posterior acetabular exposure.
What does an acetabular retractor do?
An acetabular retractor helps retract surrounding soft tissue to provide controlled access and visualization of the acetabular region during orthopedic procedures.
What is the purpose of a posterior configuration?
The posterior configuration is intended to provide a working profile suited to retraction and exposure around the posterior acetabular region.
Can this retractor be used with other hip retractors?
Yes. It can complement Hohmann, acetabular, femoral, and soft tissue retractors when different areas of the hip require exposure.
Is the Posterior Acetabular Retractor reusable?
It may be reusable when specifically manufactured and designated for reusable surgical use. Cleaning, inspection, maintenance, and sterilization should follow validated instructions.
How should the retractor be cleaned?
It should be cleaned according to the manufacturer's validated reprocessing instructions, with attention to the working end, contact surfaces, bends, and handle.
What should be inspected before use?
The working end, handle, bends, alignment, and overall surface should be checked for cracks, deformation, bending, excessive wear, or other damage.
